44
A. Conversion information
Gas type
Conversion
Connector
Marking
Input rating
Inlet gas pressure
Manifold
Pressure
(max
rating)
Minimum Maximum
Natural Gas MFX62442001 X 340 55,000BTU/hr 5.0”w.c. 10.5”w.c. 3.8”w.c.
Propane Gas MFX62442002 O 220 55,000BTU/hr 10.0”w.c. 13”w.c. 8.67”w.c.
B. Normal operating sequence of the ignition system
① Ignition controller will spark for 10 seconds after ignition
② Ignition controller will stop to spark after ignition
③
C. Check list to verify the input rate of the converted clothes dryer(See A, D)
① Conversion connector
②
③ Input and Manifold pressure (See picture 2)
④ Gas type
⑤ Altitude
D. De-rating at altitudes above 2000 ft (610m)
Dryer input ratings are based on measurements of altitude above sea level and need not be adjusted for altitude
levels up to 2000 ft (610m). Input ratings should be reduced at the rate of 4 percent for each 1000 ft (305m) above
sea level.
NOTE : THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER’S AUTHORIZED
REPRESENTATIVE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER,
PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JRISDICTION AND IN ACCORDANCE WITH THE
REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
Attach conversion data plate after
high altude conversion.
Picture 1