PROGRAMMING MODE
11. Penny increment pricing offset (Use only for card type)
This represents the cent increment price offset used when debit card is setup.
Entering set up
mode.
You will see LqC1
Button Display
Press the High Temp. button.
Press the Med Temp. or the Low Temp. button until
appears in the display.
Press the Start button.
Press the Med Temp. or the Low Temp. button until
appears in the display.
Press the Start button.
Display previous penny increment pricing oset.
Press Med Temp.(+) or Low Temp.(-) button to select value
of PIPo. (0~4)
Press the Start button.
The machine sets up the PIPo, then advances to the next process
automatically.
1. Continue to set up the next mode.
2. Stop the change of setup value and go back to ready mode.
• Coin type - Turn on/o toggle switch
• Card type - Pull the service card
• OPL/Coin type – Press “High Temp. twice
Pence increment pricing offset is available only in card type.
(It hasn’t affected on the coin type’s price setting.)
NOTE