THERMA V Split Type
8. Electric characteristics
38
Outdoor unit
Outdoor Unit and Hydro Box Unit
Model
Power Supply
for Heat Pump
Power Supply for Heater
Indoor Unit Outdoor Unit
Phase
Volts
Hz
Circuit Breaker
(A)
Back-up Heater DHW Tank Heater Circuit Breaker (A)
Capacity
(kW)
Power
Supply
Capacity
(kW)
Power
Supply
Back-up
Heater
Back-up
Heater + DHW
Tank Heater
AHNW16606A3
AHUW056A3
1~
220-240V
50Hz
30
3+3 1Ø 230V
3 1Ø 230V
35 50AHUW076A3
AHUW096A3
AHUW126A3
40 35 50AHUW146A3
AHUW166A3
AHNW16809A3
AHUW128A3
3N~
380-415V
50Hz
20 3+3+3 3Ø 400V 20 35AHUW148A3
AHUW168A3
[Power Supply for Heat Pump]
[Power Supply for Electric Heater]
Note
1.Voltage supplied to the unit terminals should be within the minimum and maximum range.
2.Maximum allowable voltage unbalance between phase is 2%.
3.Recommended circuit breaker type is ELCB (Earth Leakage Circuit Breaker).
Main
for Heat Pump
Power source
Switch box
ELCB
Outdoor
Indoor
Power &
Communication line
Main
for Heat Pump
Power source
Switch box
ELCB
Switch box
ELCB
Outdoor
Indoor
for Heater
Power source
Power &
Commication line