3. Specifications
5
THERMA V Split Type
DHW Tank Integrated Unit
Electrical Specifications
Indoor Unit Model Name AHNW16606B0 [HN1616T NB0]
Electric
Heater (1)
(1 Phase)
Power Supply V, Ø, Hz 230, 1, 50
Power Cable (Included Earth)1) No. × mm² 3C × 4.0 (H07RN-F)
Power connection wiring
2)
- L1,N,Earth
Heater Type - Sheath
Number of Heating Coil EA 1
Capacity Combination kW 2.0
Operation - Automatic
Heating Steps Step 1
Rated Current A 8.7
Maximum Current A 11.1
Fuses A 16
Maximum electrical power
3)
kW 2.52
Electric
Heater (2)
(1 Phase)
Power Supply V, Ø, Hz 230, 1, 50
Power Cable (Included Earth)1) No. × mm² 3C × 4.0 (H07RN-F)
Power connection wiring
2)
-
L1,N,Earth
(needs connect Bridge to L2 from L1)
Heater Type - Sheath
Number of Heating Coil EA 2
Capacity Combination kW 2.0 + 2.0
Operation - Automatic
Heating Steps Step 1
Rated Current A 17.4
Maximum Current A 19.9
Fuses A 20
Maximum electrical power
3)
kW 4.52
Electric
Heater (3)
(3 Phase)
Power Supply V, Ø, Hz 400, 3, 50
Power Cable (Included Earth)1) No. × mm² 5C × 2.5 (H07RN-F)
Power connection wiring
2)
- L1,L2,L3,N,Earth
Heater Type - Sheath
Number of Heating Coil EA 3
Capacity Combination kW 2.0 + 2.0 + 2.0
Operation - Automatic
Heating Steps Step 1
Rated Current A 8.7
Maximum Current A 11.1
Fuses A 16 + 16 + 16
Maximum electrical power
3)
kW 6.52
Note
1. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for
electricalwork and design. Especially the power cable and circuit breaker should be selected in accordance with that.
2. The guideline about cable is taken into account laying B2 from the table A.52.4 – IEC 60364-5-52. The cable in the installation pipe is fixed to the wall.
3. The size of Electrical Heater and the Fuses depend on the choice of the connection power.
4. Joint maximal load (circulation pumps, electronic valves ...) which can be connected to or powered by the internal unit, must not exceed the
specifiedvalue. Higher consumed parts (i.e. pumps) should have their own supply.