22
FUNCTION
ENGLISH
Dip S/W Setting (UU18W/UU24W/UU30W)
If you set the Dip Switch when power is on, the change in setting is not
applicable. The changing setting is enabled only when Power is reset.
Dip Switch
Function
1234
Normal Operation (No Function)
Forced Cooling Opertation
Saving Power Consumption (Step 1)
Saving Power Consumption (Step 2)
Mode Lock (Cooling)
Mode Lock (Heating)
Night Quiet Mode (Step 1)
Night Quiet Mode (Step 2)
Mode Lock (Cooling) + Night Quiet Mode (Step 1)
Mode Lock (Cooling) + Night Quiet Mode (Step 2)
Mode Lock (Cooling) + Saving Power Consumption (Step 1)
Mode Lock (Cooling) + Saving Power Consumption (Step 2)
Mode Lock (Heating) + Saving Power Consumption (Step 1)
Mode Lock (Heating) + Saving Power Consumption (Step 2)
When you set the dip switch, you should turn off the circuit breaker or shut the power
source of the product down.
WARNING
!
CAUTION
• Unless the applicable dip switch is set properly, the product may not work.
• If you want to set a specific function, request that the installer sets the dip switch appropriately
during installation.
!