WIRING CONNECTION
25
ENGLISH
CAUTION
!
The power cord connected to the outdoor unit should comply to IEC 60245 or HD 22.4 S4
(This equipment shall be provided with a cord set complying with the national regulation.)
GN/YL
1 Phase(Ø)
20 mm
3 Phase(Ø)
20 mm
GN/YL
NORMAL CROSS-SECTIONAL AREA
The connecting cable connected to the outdoor unit should comply to IEC 60245 or HD
22.4 S4 (This equipment shall be provided with a cord set complying with the national
regulation.)
20 mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
When the connection line between the indoor unit and outdoor unit is over 40 m, connect
the telecommunication line and power line separately.
If the supply cord is damaged, it must be replaced by a special cord or assembly available
from the manufacturer of its service agent.
Capacity(kBtu/h) Phase(Ø) Area(mm
2
)
9 / 12 / 18 / 24 / 30 1 2.5
36 / 42 / 48 / 60 1 6
36 / 42 / 48 / 60 3 2.5
1) Standard Inverter
Capacity(kBtu/h) Phase(Ø) Area(mm
2
)
18 / 24 / 30 / 36 1 2.5
2) Compact Inverter
2(N)
3
1(L)S CN-REMO
CN-REMO
CN-REMO
Terminals on the indoor unit 4
2(N)
3
1(L)S
Terminals on the indoor unit 3
2(N)
3
1(L)S
Terminals on the indoor unit 2
2(N)
3
1(L)M
Terminals on the indoor unit 1
Terminals on the
Outdoor unit
2(N)
3
1(L)
Remote
Controller
CN-REMO
2(N)
3
1(L)
2(N)
3
1(L)
2(N)
3
1(L)
2(N)
3
4
4
4
4
5
5
5
5
1(L)
• When using simultaneous Operation System,
use only one wired remote controller
in the indoor units
Simultaneous
Operation Unit 2,3,4
Main Unit1
POWER INPUT
(380V-415V3N)
TNRS
POWER INPUT
(220V-240V~)
LN
2(N)
3
1(L)
CSTDUCT, CVT