- 18 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 2 Functions & Controls
4.3 Auto restart Operation
• Whenever there is electricity failure to the unit, and after resumption of the power, unit will start in the same mode prior
to the power failure. Memorized condition are on / off condition, operating mode (cooling/ heating), set temperature and
fan speed. The unit will memorize the above conditions and start with same memorized condition.
4.2 Auto changeover operation
• The air conditioner changes the operation mode automatically to keep indoor temperature.
• When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room tempera-
ture in ±2°C with respect to setting temperature by auto change mode.
SET Temp.
+0.5°C
-0.5°C
-2°C
+4°C
+2°C
Cooling
operation
Heating operation Cooling
operation
Cooling thermo off
Heating thermo off
Switching point
Switching point