17
ERROR SYMPTOM CAUSE
OVER
CURRENT
ERROR
MAIN PWB
ASSEMBLY is out of order.
Winding in the STATOR ASSEMBLY is short-circuited.
The connector (3-pin, male, white) in the MOTOR
HARNESS is not connected to the connector
(3-pin, female, white) of STATOR ASSEMBLY.
The electric contact between the connectors
(3-pin, male, white) in the MOTOR HARNESS
and 4-pin, female, white connector in the MAIN PWB
ASSEMBLY is bad or unstable.
The MOTOR HARNESS between the STATOR
ASSEMBLY and MAIN PWB ASSEMBLY is cut (open
circuited).
The hall sensor is out of order/defective.
8
9
LOCKED
MOTOR
ERROR
Loose Ball Sensor Connector.
Ball Sensor is out of order.
Displayed only when the START/PAUSE button is first
pressed in the QC Test Mode.
10
BALL SENSOR
ERROR
The washer experienced a power failure.
The Dry Heater is out of order.
- Replace the Dry Heater
The connector of the Dry Heater is not connected
properly to the connector in the main PWB ASSEMBLY.
- Reconnect or repair the cannector.
The Dry Fan Motor is out of order.
-Replace the fan motor.
12
13
POWER
FAILURE
DRY HEATER
ERROR
EEPROM is out of order.
Displayed only when the START/PAUSE button is first
pressed in the QC Test Mode.
11
EEPROM
ERROR