20
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
option (HOT)
ABNORMAL SOUND
SOFTENER DOES NOT FLOW IN
Fix the bolt tightly.
Replace the V-belt
(4400FR3116A)
Replace the motor.
Refer to
󱄒NO WATER SUPPLY󱄓
Check the wiring on the
dispenser.
Put it in the correct
compartment.
Clean the cap and
drawer.
Is the pulley bolt loosened?
Is the belt worn?
Is there friction noise from the motor?
Is water supplied?
Are receptacles correctly connected to the
terminals of inlet valve?
Is softener put in the correct compartment of
drawer?
Is the softner cap clogged?

Related product manuals