22
1
Replace the thermistor
Push the thermistor
tightly to the rubber.
When disconnect the connector (1) on the
PWB assembly (Main) is the resistance of the
Natural connectors [󳡉(White),
󳡌(Blue White)] between 2.5
kΩ
to 180
kΩ
(105°C~0°C)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE