55
ERROR DECISION CAUSE FOR ERROR
BASIS OCCURRENCE
REMEDYERROR
• LID is opened in the
course of
intermittent spin,
normal spin or
processing
reservation.
• Wash and Spin
LED blink.
• SIGNAL
continuously ringing.
• BALL PRESSURE
SENSOR is off.
• All water level
LED blinks.
• AUTO OFF relay
S/W is out of order.
DOOR
OPEN
BALL
PRESSURE
SENSOR
AUTO
OFF
• Lid is opened during intermittent
spin or normal spin?
• Lid is opened while processing
reservation?
• Is placed magnetic in Lid-B
• Connector the BALL
PRESSURE SENSOR or
BLUE(BL) 3 pin connector to
P.W.B ASM has bad connection.
• PRESSURE S/W is bad.
(In the initial state of QC TEST
MODE, the number on the
DISPLAY is less than 63 or
more than 70)
• BLUE(BL) 1pin connector to
P.W.B ASM has bad connection.
• Closed the lid.
• Closed the lid.
• charg the Lid-B.
• Correct the connector contact.
• Replace BALL PRESSURE
SENSOR.
• Correct the connector contact.
• Change AUTO OFFswitch ASM.