The Lifestyle RNC Digital Control Part #99-DX-01
Part # 99-DX-01
The Lifestyle RNC Digital Control offers advanced features to
control your home's ventilation.
Key Features
• 2 Speed Fan setting (Low-1/High-2)
• Standby setting (Fan speed 0)
• Electronic Dehumidistat
• Four Selectable Modes of Operation
20 min. ON / 40 min. off, 20 min. ON / 40 min. recirculate *
Continuous Ventilation, Continuous Circulation *
• 20 / 40 /60 High Speed override button
• Instruction Card is inserted in the control
• Easy to read LCD Screen
• Slim-line design
• Connect to 3 wire 20 gauge low voltage wire
Setting the Control
1. Refresh the screen: use the ON/OFF button to turn the control
OFF and ON.
2. Press the SET button.
3. The “FAN” symbol flashes. SCROLL (by using the Up/Down
arrows) to select the desired fan speed (0, 1 or 2). Press the
SET button.
4. “VENT”, “20/40”, “20/40 RECIRC”, “RECIRC”or “OFF” will
flash. SCROLL to select the desired mode of operation. Press
SET button. *RECIRC is not available on all models.
**Timers will not function when mode of operation is set to
“OFF”.
Setting the Dehumidistat
1. Refresh the screen: use the ON/OFF button to turn the control
OFF and ON.
2. Press and release MODE until “RH” flashes.
3. SCROLL to the desired RH number. Press the MODE button.
20/40/60 Minute High Speed Timer
This function temporarily initiates high speed ventilation for
20, 40 or 60 minutes.
1. Refresh the screen: use the ON/OFF button to turn the control
OFF and ON.
2. Press FAN button once for 20, two times for 40, three times for
60 minutes, and four times to cancel the timer.
The Lifestyle RNC Digital Control Gives you
4 Mode Selection
The Lifestyle RNC Digital Control has 4 Operational Modes* and
2 speeds on each mode to adjust indoor ventilation levels.
Experiment with the ventilation levels in your home to evaluate
the best amount of ventilation to suit your home and preferences.
I. Continuous Ventilation Mode
This is the most popular mode since it provides continuous
ventilation within the home. You may, for example, select
Continuous Ventilation at high speed for high household
activity levels or Continuous Ventilation for lower activity
levels.
II. 20 minutes ON, 40 minutes OFF Mode
This Operational Mode will provide 20 minutes of ventilation
each hour. You may wish to use this ventilation mode in low
speed for low household activity levels or if the home is
unoccupied.
III. 20 minutes ON, 40 minutes Recirculation
Mode*
This Operational Mode provides 20 minutes of ventilation
(fresh air) and 40 minutes of recirculated air. Use this mode
only if your HRV is not connected to a forced air system (the
forced air system already circulates household air).
IV. Continuous Recirculation Mode*
This Operational Mode recirculates your household air (no
ventilation). Use this mode only if HRV is not connected to a
forced air system.
How to Synchronize the Humidity Setting on the
Lifestyle RNC Digital Control
The Lifestyle RNC Digital wall control has a feature that will
allow it to be synchronized with other humidity instruments in
your home.
1. Turn off the control with the ON/OFF Button.
2. Simultaneously press and release the ON/OFF Button and the
20/40/60 Minute High Speed Override Button.
3. Use the Up/Down buttons to adjust the Humidity indicator on
the display screen to the number of degrees difference between
your humidity measuring devise. Minus is indicated by
flashing.
4. Press the MODE button.
*Recirculation not available on all models.
Instruction card
F
an Speed
I
ndicator
20/40/60 Minute
H
igh Speed
override Button
M
ode Select
Button
O
N/OFF
Button
H
igh Speed
Override
Timer
Indicator
H
umidity
Indicator
U
p Button
S
et button
D
own Button
M
ode
Indicator
Connects to 3 wire 20 gauge
low voltage wire
4