Key Features
• The Dehumidistat measures the indoor humidity level and will
initiate high speed ventilation when the moisture level in the
home exceeds the set point on the control.
• Once the humidity in the house is reduced, the HRV will revert
back to its previous setting.
• The Dehumidistat should be set to OFF for all season except the
heating season.
• Connect to 3 wire 20 gauge low voltage wire.
Humidity Control
Your HRV will produce a dehumidifying effect when outdoor
humidity levels are lower than indoor humidity levels. Never use
the dehumidistat feature when outdoor temperatures are above 59
F (15 C).
Note: The indoor humidity level is measured at the control.
Setting the Dehumidistat
Press and release the DEHUMIDISTAT button until the
DEHUMIDISTAT LIGHT is at the desired setting. After 5
seconds the dehumidistat light will either flash or be on
continuous.
A flashing light indicates the humidity level is higher than the
setting and the unit is operating on high speed ventilation. A
continuous light indicates the humidity level is lower than the
setting. Refer to the unit's Operation & Installation Manual for
instructions on how the Dehumidistat works.
Note - Only 1 dehumidistat should be active on a system.
The Lifestyle Dehumidistat Part #99-DH-01
The Lifestyle RNC Ventilation Control Part #99-BC-01
Instruction card
Dehumidistat Indicator
LEDs
Set to the desired humidity
level. High speed ventilation
will initiate when the indoor
moisture level exceeds the set
point on the control.
Dehumidistat
Adjust button
The Lifestyle RNC Ventilation Control offers ON/OFF, High
Speed/Low speed plus an electronic dehumidistat.
Key Features
• 2 Speed Fan setting (Low/High)
• Electronic Dehumidistat
• Instruction Card is inserted in the control
• Slim-line design
• Connect to 3 wire 20 gauge low voltage wire.
Turning on the Control
Press and release the ON/OFF button. The "ON Indicator Light"
will illuminate.
Adjusting the Ventilation Speed
The unit will normally operate at low speed. Press and release the
SPEED button to initiate high speed ventilation. The "High Speed
Indicator LED" will illuminate.
Humidity Control
Your unit will produce a dehumidifying effect when outdoor
humidity levels are lower than indoor humidity levels. Never use
the dehumidistat feature when outdoor temperatures are above 59
F (15 C).
Setting the Dehumidistat
Press and release the DEHUMIDISTAT button until the
DEHUMIDISTAT LED is at the desired setting. After 5 seconds
the dehumidistat light will either flash or be on continuous.
A flashing light indicates the humidity level is higher than the
setting and the unit is operating on high speed ventilation. A
continuous light indicates the humidity level is lower than the
setting. Refer to the unit's Operation & Installation Manual for
instructions on how the Dehumidistat works.
Note - Only 1 dehumidistat should be active on a system.
Instruction card
Dehumidistat
Indicator LEDs
ON/OFF
button
High/Low
Speed
button
High Speed
Indicator LED
On
indicator
light
*Install a jumper between 2 (ON) and 3 (RED) on the HRV terminal
block to configure the ON/OFF button to ON/STANDBY. Refer to
“Setting Standby when using a Main Control” in this manual.
If the system does not have a main control installed, the HRV Terminal
Block must have a jumper installed between 2 (ON) and 3 (RED). Refer
to “Operating the HRV without a Main Control” in this manual.
5