Procedure to prime supply lines by loosening plugs and venting air.
Refer to Owner/Operator Manual C8 259 for programming the 85209 controller.
Fill feeder lines with lubricant before connecting to injectors or bearings.
Check injectors for proper operation by observing indicator stem movement.
System cycle initiated by 85530, air solenoid energizes pump, pressure switch stops pump.
Procedure to prime supply lines by loosening plugs and venting air.
Reset the delay relay to desired interval for system planning.
Fill feeder lines with lubricant before connecting to injectors or bearings.
Check injectors for proper operation by observing indicator stem movement.
Describes the 83948 Vent Valve operation and its role in pressure venting.
Details the 90942 Safety unloader, its function and factory settings.
Timer activates pump via micro-switch and solenoid valve; pressure control stops pump.
Guidance for pump losing prime, fouled parts, or pump failure.