Linear PRO Access APeX-II v2.1 Gate Controller Quick Programming Guide — Advanced Programming —
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
(THE DISPLAY
WILL FLASH)
PRESS UP
OR DOWN
TO CHANGE
OPTION
ENTER
PROGRAMMING
KEYSTROKES
SELECT
FUNCTION
CURRENTLY
SET OPTION
OPTION READY
TO CHANGE
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
CHOOSE
OPTION
OR
UP
DOWN
OR
UP
DOWN
OPTION
STORED
PRESS ENTER
TO STORE
OPTION
SELECT
FUNCTION
ENTER ENTER ENTER
OR
UP
DOWN
OR
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
PRESS UP & DOWN BUTTONS FOR 1-SECOND TO ENTER PROGRAMMING
"RL"
LEFT OR RIGHT
HAND OPERATION
"PM"
SINGLE OR
DUAL GATE
"AC"
AUTO CLOSE
TIMER
"RP"
RUN ALARM
PRE-START ALARM
"OC"
MAXIMUM OPEN
CURRENT
"CC"
MAXIMUM CLOSE
CURRENT
"AD"
ADVANCED
PROGRAMMING
"BD"
BRAKE
DELAY TIME
"OR"
OPEN/RESET
INPUT
"TG"
ANTI
TAILGATE
"RT"
MAXIMUM
RUN TIMER
"SB"
SINGLE BUTTON
INPUT SETUP
"SM"
STAGGER
MODE
"ST"
STAGGER
TIME
"AR"
AUXILIARY
RELAY MODE
"RD"
REVERSE
DELAY TIME
"CP"
CONSTANT
PRESSURE MODE
"LP"
LOW POWER
MODE
POWER
FAILURE MODE
"FS"
"SP"
SHADOW LOOP
OPEN PREVENTION
"SS"
SOFT START/STOP
DURATION
"CT"
RESET CYCLE
COUNT
"MA"
MAINTENANCE ALERT
TRIGGER
"MT"
MID-TRAVEL
STOP POSITION
APEX FUNCTION
DISPLAY INDICATIONS
"RA"
RADIO
ENABLE
"TL"
LEARN
TRANSMITTERS
"TD"
DELETE
TRANSMITTERS
"ML"
LEARN MGT
TRANSMITTERS
"MD"
ERASE MGT
TRANSMITTERS
"CL"
RESET TO
FACTORY DEFAULTS
MOTOR TYPE
SELECTION
"MO"
ANTI-TAILGATE
ENABLE
"AT"
"OT"
OBSTRUCTION
DETECTION TYPE, b1, b2
"RC"
REMOTE CLOSE
OBSTRUCTION ACTIVE
"OO"
OPEN OBSTRUCTION
INPUT ACTIVE
"MM"
MGT MONITIRING
FUNCTION
"RO"
REMOTE OPEN
OBSTRUCTION ACTIVE
"CO"
CLOSE OBSTRUCTION
INPUT ACTIVE
FUNCTION
ADVANCED PROGRAMMING FUNCTIONS
WILL NOT BE DISPLAYED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
ADVANCED
PROGRAMMING
"AD"
ADVANCED PROGRAMMING OPTIONS
WILL BE DISPLAYED
NOTE: ADVANCED PROGRAMMING
WILL STAY ENABLED AFTER
EXITING PROGRAMMING UNTIL
THE GATE CYCLES 50 TIMES
FUNCTION
SINGLE INPUT WILL OPEN OPERATOR,
IF OPERATOR IS ALREADY OPEN, SINGLE
INPUT WILL CLOSE OPERATOR
SINGLE INPUT WILL CYCLE OPERATOR
IN ORDER OF OPEN-STOP-CLOSE-STOP
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SINGLE BUTTON
INPUT SETUP
"SB"
FUNCTION
SETS THIS OPERATOR FOR
DELAYED OPEN
DISABLES STAGGER FUNCTION
SETS THIS OPERATOR FOR
DELAYED CLOSE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
STAGGER
MODE
"SM"
NON-LRA DUAL
GATES ONLY
FUNCTION
SET STAGGER DELAY VALUE
1 TO 99 SECONDS
STAGGER TIMER DISABLED
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
STAGGER
DELAY TIME
"ST"
NON-LRA DUAL
GATES ONLY
FUNCTION
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP OR DOWN TO CHANGE THE
MAXIMUM RUN TIME (10-99 SECONDS)
OPTIONS
MAXIMUM RUN
TIMER
DISPLAY SHOWS CURRENT
MAXIMUM RUN TIME SETTING
ENTER
ENTER
PRESS ENTER TO STORE THE VALUE
"RT"
FUNCTION
AUXILIARY RELAY USED FOR
MAGLOCK CONTROL
AUXILIARY RELAY DISABLED
AUXILIARY RELAY USED FOR
TICKET DISPENSER CONTROL
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUXILIARY
"AR"
AUXILIARY RELAY USED FOR
WARNING STROBE LIGHT
AUXILIARY RELAY USED FOR
CONNECTION TO ALARM DEVICE
AUXILIARY RELAY USED FOR
MAGLOCK OR SOLENOID CONTROL
3 SECOND DELAY TO RE-ENERGIZE
FUNCTION
SET TIMER VALUE
1 TO 9 SECONDS
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
REVERSE
DELAY TIME
"RD"
FUNCTION
SET TIMER VALUE
0 TO 3 SECONDS
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
BRAKE
"BD"
FUNCTION
CONSTANT PRESSURE SET TO OFF
(MOMENTARY PRESSURE ON)
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
CONSTANT
"CP"
OPEN BUTTON SET FOR
CONSTANT PRESSURE
CLOSE BUTTON SET FOR
CONSTANT PRESSURE
OPEN AND CLOSE BUTTONS BOTH SET
FOR CONSTANT PRESSURE
NOT FOR
BARRIER GATES
LOW POWER MODE DISABLED
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
LOW POWER
MODE
"LP"
LOW POWER MODE #1
RADIO WILL WAKE AND ACTIVATE,
REVERSE LOOP WILL JUST WAKE
LOW POWER MODE #2 - RADIO OR
OPEN LOOP WILL WAKE AND ACTIVATE,
REVERSE LOOP WILL JUST WAKE
THE FIRE DEPARTMENT INPUT
WILL ALWAYS WAKE UP CONTROLLER
FUNCTION
STANDARD OPERATION
SHADOW LOOP INHIBITS CLOSING ONLY
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SHADOW LOOP
OPEN PREVENTION
"SP"
OPEN INHIBIT ON, SHADOW LOOP INHIBITS
OPENING AND CLOSING
FUNCTION
SET TO FAIL SAFE MODE
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
POWER
FAILURE MODE
"FS"
SET TO FAIL SECURE MODE
DC MODELS
ONLY
SET TO OPEN IMMEDIATE MODE
SET TO CLOSE
IMMEDIATE MODE
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
NOT FOR
BARRIER GATES
FUNCTION
SETS THIS MAINTENANCE ALERT TRIGGER
FOR 5, 10, 15, OR 25 THOUSAND CYCLES
DISABLES THE MAINTENANCE ALERT
FUNCTION
RESETS THE MAINTENANCE ALERT
INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
MAINTENANCE
ALERT TRIGGER
"MA"
FUNCTION
PRESS ENTER TO START THE CYCLE COUNT DISPLAY
1ST DISPLAY
NOTE: PRESS ENTER FOR 2 SECONDS
WHILE THE "CT" FUNCTION IS DISPLAYED
TO RESET THE CYCLE COUNT TO ZERO
RESET CYCLE
COUNT
"CT"
2ND DISPLAY3RD DISPLAY4TH DISPLAY
EXAMPLE ABOVE SHOWS 10,420 CYCLES
DECIMAL POINT LIT
ON 4TH DISPLAY
SET SOFT START DURATION TIME
FROM 1 TO 10 SECONDS
SOFT START DISABLED
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
SOFT START/STOP
DURATION
"SS"