Section 6:
Troubleshooting
Observation
Causes/Remedies
No Water Flow
No Green Power Light (under dial)
No power; unit not plugged into required 100-120V or 200-240V outlet.
Fuse blown (2 A slow blow fuse).
Remedy – Replace fuse
Electronics failure.
Remedy – Call your Authorized Dealer
Four blue and red Indicator Lights
Flash right-left-right
The system in the 90 second filling stage immediately following powering
The system is conditioning the LINX 50 TDS cartridge (90 minutes)
Clicking noise for 10 sec after
regeneration
The LINX system is cleaning its valves – this is normal behavior
No Product Water Flow
(Green light on; no indicator lights are
flashing when faucet is opened)
Faucet is mounted 13 ft (4 meters) or more above the LINX system
Remedy – install the LINX system at <13 ft (4 meters) below faucet
Tubing connections are incorrect
No Product Water Flow
Indicator lights B, C and D flashing
Top Enclosure is installed incorrectly
Remedy – Assure that top enclosure is fully seated
No Product Water Flow
Indicator lights A, B, C and D flashing
Clogged drain line (drain valve(s) or tubing)
No feed pressure (alarm will automatically clear when feed P is restored)
Remedy – If occurs again after re-powering, call Authorized Dealer
No Product Water Flow
Indicator lights A, B and D flashing
AND audible buzzer
Internal leak detected (or external leak if this sensor is attached)
Remedy – Turn off the feed water and call Authorized Dealer
No Product Water Flow
Indicator lights A, C and D flashing
No power to LINX cell (no TDS reduction)
Remedy – If occurs again after re-powering, call Authorized Dealer
LED B (red) continuously on
(when system is idle)
LINX 120 Sediment/ Carbon filers have surpassed their usage volume limits
Remedy – Call the Authorized Dealer to replace cartridges and/or filters
LED C (blue) continuously on
(when system is idle)
LINX 50 TDS cartridge has surpassed its usage volume limit
Remedy – Call the Authorized Dealer to replace cartridges and/or filters
Objectionable Taste or Odor
LINX 120 Carbon filter missing or exhausted.
Remedy – Call the Authorized Dealer to replace carbon filter
Poor TDS reduction
Dial-a-Taste knob set to high mineral level (rotated clockwise).
Missing or damaged bottom LINX 50 TDS cartridge o-ring(s)
LINX TDS cartridge needs replacement.
Contact your Local Authorized Dealer for service and replacement components