05-3044-A
9
Section 6:
Troubleshooting
Observation
Causes/Remedies
No Water Flow
No Green Power Light (under dial)
• No power; unit not plugged into required 100-120V or 200-240V outlet.
• Fuse blown (2 A slow blow fuse).
Remedy – Replace fuse
• Electronics failure.
Remedy – Call your Authorized Dealer
Four blue and red Indicator Lights
Flash right-left-right
• The system in the 90 second filling stage immediately following powering
• The system is conditioning the LINX 50 TDS cartridge (90 minutes)
Clicking noise for 10 sec after
regeneration
• The LINX system is cleaning its valves – this is normal behavior
No Product Water Flow
(Green light on; no indicator lights are
flashing when faucet is opened)
• Faucet is mounted 13 ft (4 meters) or more above the LINX system
Remedy – install the LINX system at <13 ft (4 meters) below faucet
• Tubing connections are incorrect
No Product Water Flow
Indicator lights B, C and D flashing
• Top Enclosure is installed incorrectly
Remedy – Assure that top enclosure is fully seated
No Product Water Flow
Indicator lights A, B, C and D flashing
• Clogged drain line (drain valve(s) or tubing)
• No feed pressure (alarm will automatically clear when feed P is restored)
Remedy – If occurs again after re-powering, call Authorized Dealer
No Product Water Flow
Indicator lights A, B and D flashing
AND audible buzzer
• Internal leak detected (or external leak if this sensor is attached)
• Remedy – Turn off the feed water and call Authorized Dealer
No Product Water Flow
Indicator lights A, C and D flashing
• No power to LINX cell (no TDS reduction)
• Remedy – If occurs again after re-powering, call Authorized Dealer
LED B (red) continuously on
(when system is idle)
• LINX 120 Sediment/ Carbon filers have surpassed their usage volume limits
Remedy – Call the Authorized Dealer to replace cartridges and/or filters
LED C (blue) continuously on
(when system is idle)
• LINX 50 TDS cartridge has surpassed its usage volume limit
Remedy – Call the Authorized Dealer to replace cartridges and/or filters
Objectionable Taste or Odor
• LINX 120 Carbon filter missing or exhausted.
Remedy – Call the Authorized Dealer to replace carbon filter
Poor TDS reduction
• Dial-a-Taste knob set to high mineral level (rotated clockwise).
• Missing or damaged bottom LINX 50 TDS cartridge o-ring(s)
• LINX TDS cartridge needs replacement.
Contact your Local Authorized Dealer for service and replacement components