Quick Start Guide
READ THIS INSERT AND ALL OF
THE LABELLING PROVIDED WITH
THE CGM APP BEFORE
HANDLING THE SENSOR KIT.
Step 1
Select Insertion Area
Abdomen: Avoid the
waistband, abdominal wrinkle,
scars, insulin injection
induration, belt-wearing area,
and stretch marks. Also, make
sure that your insertion site is
at least 5cm away from your
navel.
Upper arm: the back of the
upper arm (Don’t insert into the
muscles on the outer side of
the upper arm.)
Step 2
Sterilize: Before the insertion,
clean the insertion site with an
alcohol wipe and let it dry
completely.
Step 3
Unscrew the cover from the
sensor applicator and set it
aside.
Step 4
Align the opening of the
applicator with the skin where
you want to apply it and press
it tightly on the skin. Then
press the implantation button
of the applicator, wait for a
few seconds after hearing the
sound of the spring retreating,
to make the sensor stick on
the skin, and the puncture
needle in the applicator will
automatically retreat.
Step 5
Gently pull the sensor
applicator away from the
body, and the sensor should
now be attached to the skin.
Step 6
After installing the sensor,
make sure that the sensor is
firmly in place. Put the cover
back on the sensor applicator.
Description
The Sensor is located inside the Sensor
Applicator. Follow the instructions
to prepare and apply the Sensor on the
back of your upper arm. The Sensor
has a small, flexible tip that is inserted just
under the skin. The Sensor can
be worn for up to 15 days.
For more specific operations, please refer
to the user guide in the LinX app.
1
2
3
4
5
6
For use with LinX App
LinX
Indication for use:
The Continuous Glucose Monitoring
System sensor is a real time, continuous
glucose monitoring device. When the
system is used together with compatible
devices, it is indicated for the
management of diabetes in adult people
(age 18 and older). It is designed to
replace finger stick blood glucose testing
for diabetes treatment decisions.
Interpretation of the system results
should be based on the glucose trends
and several sequential readings over
time. The system also detects trends
and tracks patterns, and aids in the
detection of episodes of hyperglycemia
and hypoglycemia, facilitating both acute
and long-term therapy adjustment.
Contraindications:
The Continuous Glucose Monitoring
System must be removed prior to
Magnetic Resonance Imaging (MRI).
The Continuous Glucose Monitoring
System was not evaluated for the
Pregnant women.
Product name:
Continuous Glucose Monitoring
System Sensor
Product Model:
GX-01,GX-02,GX-01S,GX-02S
For use with:
RC2107, RC2108,
RC2109, RC2110 CGM app
Question and Answer IconNeed help?

Do you have a question about the Linx GX-01 and is the answer not in the manual?

Linx GX-01 Specifications

General IconGeneral
BrandLinx
ModelGX-01
CategoryBlood Glucose Meter
LanguageEnglish