Rev: 06.01.23 Page 6 CCD-0007029
B. If installing on the T-molding, start on one side of the front of the slide-out by placing one of the
two access brackets (Fig. 7A) at the very bottom corner of the T-molding, (Fig. 7B) as close to the
outside of the T-molding as possible without going over the corner mold (Fig. 7C).
NOTE: Make sure the screws do not go over the roof line.
2. Use silicone sealant or butyl tape on the back of the plate prior to installing.
Fig. 7
A
A
A
3. Fasten the mounting bracket to the slide-out exterior wall using the five provided #10 -13 x 1 1/4”
recessed square head screws (Fig. 8).
Fig. 8
Falling slide topper access brackets can cause personal injury, product and/or property damage.
Slide topper access brackets are installed loose on the access plate until nal installation. Make sure
access brackets are secure enough to prevent falling from the access plate.