500/300 Series
LISA 500/300 SERIES 201 07 AEN REV.3
User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lisa 500 Series and is the answer not in the manual?

Lisa 500 Series Specifications

General IconGeneral
TypeSteam Steriliser
Weight20 kg
DisplayLCD
Power Supply220-240 V, 50/60 Hz
Sterilisation Temperature121°C / 134°C
MaterialStainless steel

Summary

Introduction and Safety Information

Scope of the User Manual

Defines the purpose and intended audience of this user manual.

Applicable European Directives and Norms

Lists the European directives and standards the sterilizer complies with.

Intended Use of the Sterilizer

Specifies the applications and environments where the sterilizer can be used.

Symbols Displayed on the Sterilizer

Explains the meaning of various symbols used on the sterilizer and in the manual.

General Safety Recommendations

Provides essential safety guidelines for operating and maintaining the sterilizer.

Unit Description and Components

Front View of the Sterilizer

Identifies and describes the components visible on the front of the sterilizer.

Service Door Components

Details the parts and connections accessible through the service door.

Rear View of the Sterilizer

Identifies and describes the components located on the rear of the sterilizer.

Internal Water Tanks Description

Explains the function, capacity, and features of the clean and used water tanks.

Chamber Rack Usage

Instructions on how to insert, use, and reverse the chamber rack.

Usable Chamber Space

Specifies the internal dimensions and volume available for sterilization loads.

Installation Procedures

General Setup Instructions

Guidelines for placing the sterilizer on a suitable surface and ensuring ventilation.

Securing Sterilizer with Safety Bracket

Instructions for installing a safety bracket to prevent tipping.

Electrical Power Supply Requirements

Details on electrical connections, voltage, and safety precautions.

Optional Printer Connection

Steps for connecting and configuring a standard printer for cycle data.

Optional Label Printer Connection

Instructions for connecting and setting up an optional label printer.

Optional Demineralizer System

Information regarding the optional automated demineralized water supply.

Connecting External Water Supply

Procedure for connecting the demineralizer to the sterilizer.

Optional Continuous Draining

Instructions for setting up a continuous drain for used water.

Connecting the Drain Tube

Steps for connecting the drain tube for continuous draining.

Getting Started and Basic Operation

Understanding the User Interface

Overview of the touch-screen display, icons, and navigation.

Initial Warnings and Sleep Mode

Explanation of warning messages and the automatic sleep mode function.

Setting the Date and Clock

Procedure for setting the internal date and time for accurate logging.

Filling the Clean Water Tank

Detailed instructions for filling the clean water tank.

Manual Filling Procedure

Step-by-step guide for manually filling the clean water tank.

Automated Water Supply (Optional)

Describes how the optional automated system fills the clean water tank.

Draining the Used Water Tank

Instructions for emptying the used water tank.

Manual Draining Procedure

Step-by-step guide for manually draining the used water tank.

Memory Card Usage Overview

Introduction to the memory card for cycle data recording and management.

Inserting and Removing Memory Card

Instructions on how to properly insert and remove the memory card.

Programming and Settings

Setup Menu Overview

Lists the available options within the main setup menu.

Language Selection

How to choose the user interface language.

Sleep Mode Configuration

Setting the time interval before the sterilizer enters sleep mode.

Printer Setup

Configuration options for connecting and using a printer.

Label Printer Setup

Configuration options for the optional label printing system.

Automatic Printing Settings

Configuring the number of labels to print automatically after a cycle.

Manual Printing Settings

Configuring manual label printing after checking the load.

Storage Time Setting

Setting storage duration to automatically calculate expiry dates on labels.

User Name Setting

Inputting the operator or office name for cycle reports.

Date and Clock Setting

Procedure for setting the sterilizer's internal date and time.

Date Format Selection

Choosing the preferred display format for dates.

Clock Format Selection

Choosing the preferred display format for time (12h/24h).

Display Contrast Adjustment

Adjusting the screen contrast for optimal visibility.

Display Backlight Adjustment

Adjusting the screen backlight intensity or color.

Acoustic Tones Configuration

Setting the volume or type of audible tones for various operations.

Delayed Cycle Start

Setting a specific future time for a sterilization cycle to begin.

Cycle History Review

Accessing and viewing data from previously completed sterilization cycles.

Utility Functions Access

Accessing system utilities for information and card management.

System Information Display

Viewing technical details about the sterilizer's model and firmware.

Memory Card Formatting

Procedure for formatting the memory card to erase all data.

Running Sterilization Cycles

Available Sterilization Cycle Programs

Overview of the different sterilization cycle types and their applications.

Starting a Sterilization Cycle

Step-by-step guide on how to select and initiate a sterilization cycle.

ECO-B Option Explained

Details on the ECO-B option for faster cycles with limited loads.

Monitoring Cycle In-Progress

Information displayed on the screen during an active sterilization cycle.

End of Cycle Procedures

What happens and is displayed when a sterilization cycle is completed.

Manual Cycle Stop

Instructions on how to manually abort an ongoing sterilization cycle.

Real-Time Cycle Data Information

Viewing live technical parameters and measurements during a cycle.

Cycle Data Summary Review

How to view a summary of cycle parameters after completion.

Display Messages and Alarms

Display Messages Overview

Explains the different types of messages displayed on the sterilizer's screen.

Warning Messages

Interprets messages indicating immediate operational issues or required actions.

Information Messages

Explains messages providing status updates or additional details.

Maintenance Messages

Interprets messages related to required maintenance or consumable replacement.

Alarm Conditions

Details on alarm events and their impact on the sterilization process.

Alarm Code Table

A reference table listing alarm codes, descriptions, and troubleshooting actions.

Maintenance Procedures

Maintenance Overview

General information on user-performed and technician maintenance.

Maintenance Program Schedule

Outlines scheduled maintenance tasks and their frequencies.

Cleaning the Door Seal

Procedure for cleaning the door seal with a mild detergent.

Cleaning the Chamber and Components

Instructions for cleaning the sterilization chamber and its internal parts.

Cleaning the Chamber Filter

Procedure for removing and cleaning the chamber filter.

Cleaning External Sterilizer Surfaces

Guidelines for cleaning the exterior of the sterilizer unit.

Replacing the Bacteriological Filter

Instructions on how to replace the bacteriological filter.

Replacing the Dust Filter

Instructions on how to replace the dust filter.

Cleaning the Water Tanks

Procedure for thorough cleaning of both the clean and used water tanks.

Replacing the Door Seal

Step-by-step guide for replacing the door seal to ensure proper sealing.

Authorized Service Technician Maintenance

Details on periodic servicing performed by qualified technicians.

Memory Card and Data Management

Memory Card Usage Overview

Introduction to the memory card for cycle data recording on 300 Series.

Memory Card Technical Characteristics

Specifications for compatible memory cards, including tested brands and capacity.

Reading Data with PC/MAC

Instructions on how to save, view, and print data from the memory card.

PC/MAC Hardware Requirements

Minimum hardware and software specifications for PC/MAC data management.

Connecting the USB Card Reader

Steps for connecting the external USB card reader to a computer.

Saved File Format

Information about the file extension (.htm) and viewer for saved sterilization reports.

Control Code Explanation

Explanation of the control code's purpose for data identification and integrity.

File Name Structure

Details on how file names are automatically generated for cycle reports.

Directory Name Structure

Describes the organization of directories on the memory card for data storage.

Memory Card Management

Procedures for checking, error handling, and formatting memory cards.

Saving a File to Memory Card

Instructions on how cycle data is automatically saved to the memory card.

Troubleshooting and Disposal

Troubleshooting Common Problems

A table listing common issues, potential causes, and solutions for the sterilizer.

Recycling and Disposal Instructions

Guidelines for the environmentally responsible disposal and recycling of the unit.

Appendices

Appendix 1: Technical Characteristics

Detailed technical specifications of the sterilizer, including electrical and physical data.

Appendix 2: Sterilization Load Preparation

Instructions on cleaning and preparing instruments and loads for sterilization.

Appendix 3: Dental Handpiece Maintenance

Specific procedures for the cleaning, lubrication, and packaging of dental handpieces.

Appendix 4: Bowie & Dick Test Procedure

Guide on performing and interpreting the Bowie & Dick test for steam penetration.

Appendix 5: Helix Test Procedure

Guide on performing and interpreting the Helix test for hollow load sterilization.

Appendix 6: Vacuum Test Procedure

Instructions for conducting and interpreting the vacuum leakage test.

Appendix 7: Water Quality Requirements

Specifications and guidelines for the quality of water used in the sterilizer.

Appendix 8: Cycle Data Report Example

An example of a detailed report generated after a sterilization cycle.

Appendix 9: Accessories List

A list of available accessories and their corresponding ordering numbers.

Appendix 10: Helix Test Documentation Form

A form for documenting the results of Helix tests performed.

Related product manuals