Loading...
99
Parameter
Name
Description
Setting Range
d1-06
Middle Output
Frequency
Default: <1>
Min.: 0.0 Hz
Max.: Defined by d1-
02
d1-07
Middle Output
Frequency
Voltage
Default: <1>
Min.: 0.0 V
Max.: 255.0 V <3>
d1-08
Minimum
Output
Frequency
Default: <1>
Min.: 0.0 Hz
Max.: Defined by d1-
02
d1-09
Minimum
Output
Frequency
Voltage
Default: <1>
Min.: 0.0 V
Max.: 255.0 V <3>
d1-10
Middle Output
Frequency 2
Default: 0.0 Hz
Min.: 0.0 Hz
Max.: Defined by d1-
02
d1-11
Middle Output
Frequency
Voltage 2
Default: 0.0 V
Min.: 0.0 V
Max.: 255.0 V <3>
d1-23
Mode setting for
V/F separation
0 : V/F
1 : V/F complete separation
2 : V/F half separation
Default: 0
Min.: 0
Max.: 2
d1-24
Voltage source
for V/F
separation
0 : Setting by d1-25
1 : Analog setting corresponds to the E3-01 or
E3-07 = 20
Default: 0
Min.: 0
Max.: 1
d1-25
Voltage digital
setting for V/
F separation
Setting voltage digital for V/F separation
Default: A1-03
Min.: 0V
Max.: Defined to the
rated motor voltage
d1-26
Voltage rise time
of V/F separation
Setting voltage rise time for V/F separation
Default: depends on
the HP
10HP and below: 10s
15HP and 20HP: 15s
25HP and above: 20s
Min.: 0.1 s
Max.: 1000.0 s
d1-27
Voltage decline
time of V/F
Setting voltage decline time for V/F separation
Default: depends on
the HP