103
Parameter
Name
Description
Setting Range
26 : Motor Overload Pre-Alarm (oL1)
27 : Drive Overheat Pre-Alarm (oH)
28 : Retain
29 : Mechanical Weakening Detection
(Normal Open)
31During Torque Limit (Currenty Control)
32During Speed Limit
33During Speed Limit Circuit Operation (For
Torque Control)
34Zero Speed Holding Stop
35: During Frequency Output
36: Drive Enabled
37: Watt Hour Pulse Output
38 : Local/Remote Mode
39 : During Speed Search
40 :PID Feedback Low
41 :PID Feedback High
42 : During KEB Operation
43 :Retain
44 : During Fast Stop
45 : Internal Cooling Fan Alarm
49 : Brake control (Desired frequency attained)
50 : Set D1 as pulse output
51 : Automatic operation cycle is completed
<8>
52 : Automatic operation phase is completed
<8>
100 to 152: 0 to 52 with Inverse Output
E2-05
Watt Hour
Output Unit
Selects the output unit for the terminal
assigned to E2-00 or E2-03=37 for one pulse
signal.
0: 0.1 kWh units
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
Default: 0
Range: 0 to 4
E2-06
Relay 1 On Delay
The definition of a relay1 on delay time.
Default: 0.0s
Min.: 0.0s
Max.: 3600.0s
E2-07
Relay 1 Off Delay
The definition of a relay1 off delay time.
Default: 0.0s
Min.: 0.0s