Parameter
Name
Description
Setting Range
0 : Disabled (No Alarm)
1 : Enabled (Alarm)
P7-13
DC Braking Level
Setting
Sets the DC braking transistor level.
Default: Determined
by d1-00 <3>
Range: 330 to 400V
<3>
P7-14
CHARGE mode
selection
0: First to run
1: Regularly when the inverter is stopped
Default:0
Min.:0
Max.:1
Group n, Special Adjustments
n1: Hunting Prevention
n1-00
Hunting
Prevention
Setting
0 Disabled
1 Enabled
Default: 1
Range: 0, 1
n1-01<4>
Hunting
Prevention Gain
If the motor oscillates during light load,
gradually increase this value by units of 0.1. If
the motor stalls, gradually decrease this value
by units of 0.1.
Default: 2
Min.: 2
Max.: 5
n1-02
De-hunting gain
during
deceleration
De-hunting gain during deceleration
Default: 0.20
Min.: 0.00
Max.: 2.50
n1-03
Minimum
frequency of de-
hunting
Minimum Operating Frequency of De-hunting
Default: 5.00Hz
Min: 0.00
Max: 60.00Hz
n3-04
Overexcitation
deceleration gain
Adjusting the V/f characteristics during
overexcitation deceleration
Default: 1.10
Range: 1.00~2.50
n3-06
High slip
elimination
current level
If OC (overcurrent), OL1 (motor overload),
and OL2 (overload of the inverter) occur
during overexcitation, reduce the current level
and the rated current of the inverter is 100%.
Default: 100 %
Min.: 0 %
Max.: 150 %
Group o, Keypad Function Settings
o1: Display Setting
o1-00
Frequency
Command
Setting/Display
Unit
0 : Use units of 0.01 Hz
1 : Use units of 0.01% (100% as maximum
output frequency)
2 : Use units of min-1 (automatically calculated
by maximum output frequency and number of
Default: 0
Range: 0 to 3