7
1500 -4600W Model (5000-12000BTU/h Model)
5000-5100W Model (17000-18000BTU/h Model)
Connect diagram
6000-10000W Model (21000-36000BTU/h Model)
2
L
N
N
L
Black
Indoor unit terminal
Blue
Connecting
cable
Brown
Yellow/Green
Blue
Brown
Black
Blue
Brown
Gray
N
L3
L2
2
L1
L
N
L
3
2
4
5
R1
6
R2
Outdoor unit
terminal
安装说明
Yellow/Green
POWER
SOURCE
N
Blue
N
Blue
POWER
SOURCE
L
Brown
L
Brown
Cool only type
Heat pump type
(T3)(T3)
Indoor unit terminal
Outdoor unit
terminal
Black
Yellow/Green
2
N
2
N
Connecting
cable
Indoor unit terminal
Gray
Blue
Yellow/Green
3
2
N
3
2N
4
R1
R2
4
Brown
Blue
Brown
Brown
Cool only type
Heat pump type
Plug housing 1
Plug housing 1
Blue
Cool only type
OR
Connecting
cable
Outdoor unit terminal
Brown
Yellow/Green
Blue
3
2
N
3
2N
4
4
Brown
Black
Gray
Heat pump type
L
2
N
L
2A
2B
N
Connecting
cable
Indoor unit A terminal
L
2
N
Yellow/Green
Blue
Brown
Black
Black
Indoor unit B terminal
Outdoor
unit terminal
Connecting
cable
Indoor unit terminal
Outdoor unit terminal
Blue
Brown
Black
2
L
N
NL
2
Yellow/Green
Dual Split Model
Power
source
L
2
N
2A
2B
N
Connecting
cable
L
2
N
Yellow/Green
Blue
Brown
Black
Outdoor
unit terminal
Power
source
L
N
L
Blue
Brown
Inverter Type
Dual Split Inverter Type
Indoor unit A terminal
Indoor unit B terminal
Cool only and heat pump type
Heat pump type
Heat pump type
Plug housing 1
Blue
Plug housing 2
Plug housing 1
Plug housing 2
Blue
2
N
2
N
Yellow/Green
Indoor unit terminal
Brown
Connecting cable
Cool only type
Indoor unit terminal
Blue
Yellow/Green
3
2
N
3
2N
4
R1
R2
4
Brown
Blue
Brown
Plug housing 1
Blue
Brown
Heat pump type
Outdoor unit terminal
OR
Outdoor unit terminal
Blue
Black
Gray
Brown
Blue
3
2
N
3
2N
4
4
Brown
Heat pump type
Plug
housing 1
Plug
housing 2
Brown
Blue
3
2
N
3
2N
4
4
Heat pump type
Plug
housing 1
Plug
housing 2
Connecting cable
Yellow/Green
OR
Plug
housing 1
Plug
housing 1
Plug
housing 2
Connecting cable
Indoor unit terminal
2
N
L
N
N
2
L2
L1
L
Brown
Black
Blue
Blue
Yellow/Green
Brown
3
Brown
Black
Brown
Blue
Gray
Yellow/Green
N
L3
L3
2
L
3
2
4
L2
2
L1
L
5
R1
6
R2
Outdoor unit terminal
2
NL
Blue
Yellow/Green
3
Brown
Black
Brown
N
L 2 3 4
Indoor unit terminal
Connecting cable
Gray
Connecting cable
Outdoor unit terminal
Heat pump type Heat pump type
OR