7
● While weighing, press HOLD and the indicator will hold the current weight on the screen
until HOLD is pressed again
3. Auto Hold: If the weight on the scale is above 20d and is stable, the indicator will
hold that weight on the screen for 3 seconds then go back to general weighing
● Pressing the hold key is unnecessary, holding is done automatically when the scale is
stable
4. Average Hold: Used for animal weighing, the indicator will display the average
weight sampled from 1-9 seconds (Set in the HAt parameter setting)
● Add animal to scale and press HOLD
● Indicator screen will show “LOC” for 1-9 seconds, then display the average weight
from those seconds
● Press HOLD again to exit holding mode
5. Auto Average Hold: Used for animal weighing, the indicator will display the
average weight sampled from 1-9 seconds without the need to press the HOLD key.
If the weight on the scale is above 20d (scales division x 20) and is stable, the
indicator will start grabbing the average weight sampled from 1-9 seconds (Set in the
HAt: parameter setting). In parameter Hadt you can set a determined loading time
from 1-9 seconds. This is the time you have to load the animal before the scale
begins to take the average weight.
● Add animal to scale. Once weight is added to the scale, the scale will wait the set
loading time and then the Indicator screen will show “LOC” for 1-9 seconds
● It will then display the average weight from those 1-9 seconds for 3 seconds and
then repeat the process