Floor Protector Construction (Hearth)
For Floor Protector minimum dimensions refer to following data. The floor protector must extend at least 300mm
beyond the door opening of the heater and 200mm to each side of the door opening. Floor Protector specs (AS/NZS
2918:2001) minimum ash hearth only eg. Ceramic tile glued to a heat sensitive floor. A provision has been made at the
rear of the pedestal for seismic restraint by bolting through the two holes through the hearth and floor.
Clearance Requirements
The Micros ash Hearth has been tested to the Australian/New Zealand Standard AS/NZS 2918:2001 and all
installations must be in accordance with the minimum clearances to combustibles indicated in these instructions.
The minimum clearances to combustibles may be reduced if the combustible walls are shielded with an approved
non-combustible material. Details of suitable shielding materials and appropriate clearance reduction factors are
present in Section 3 of AS/NZS 2918:2001.
Minimum clearances to combustibles in millimetres AS/NZS 2918:2001
NEW ZEALAND
A B C D E
F G H J K L M
N
Without flue shield
275
195
171
136
50
418
470
346
822
957
1028
864
539
With Logaire Double flue shield
100
220
171
136
50
243
495
346
822
782
1028
864
539
All specifications are subject to change or variation without notification.
LOGAIRE
Micros
specifications Ash Hearth
Question and Answer IconNeed help?

Do you have a question about the Logaire Micros Ash Hearth and is the answer not in the manual?

Logaire Micros Ash Hearth Specifications

General IconGeneral
BrandLogaire
ModelMicros Ash Hearth
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals