or at least twice a year.
Cleaning
Clean your crane and accessories regularly, but:
Do not use aggressive cleaning agents.
Use only cleaning agents with pH between 5-9.
Use Max water temperature: + 50 C
Use Max pressure: 140 bar
Minimum distance between nozzle and the surface: 40 cm
Never use a high pressure jet cleaner on electronic parts, plastic components, signs, bearings,
control valves, cylinders or the oil tank. Only the cranes surface may be cleaned with a high-
pressure jet cleaner.
12.3.1. Daily inspection
Stop buttons and stop functions
Use the crane and its safety system to make sure that the stop buttons, motor stop, dump valve,
tilt sensor, TWI and CWI are undamaged and working properly.
OLP [option]
Operate the OLP function and verify that is working correctly.
Control levers, joysticks, pedals and control rods
Check that they are undamaged and working properly.
Hydraulic system
Check that there are no leaks from the hydraulic hoses, cylinders, valves, bottom of the base,
joint of the column, lines and connections of the base.
Oil tank level
To check the level in the oil tank:
Put the vehicle on level ground with the crane in transport position.
If necessary, top up.
Base oil level
Check the oil level in the base.
If necessary, top up.
Add-on equipment
Check the cables, cable connections, the cable guides and the attachment points for the add-on
equipment.
Maintain all add-on equipment, auxiliary equipment etc. according to the instructions supplied
with it.