EasyManua.ls Logo

Lombardini CHD series - Cooling System Overview; Cooling system layout

Lombardini CHD series
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 64 - Workshop Manual LDW CHD _ cod. 1.5302.345 - 6° ed_rev. 05
1
6
7
8
9
4
5
3
2
10
140
7
COOLING SYSTEM LAYOUT
Components:
1)Coolantllcap  6) Thermostat
2) Expansion tank 7) Fan
3) Cylinder block 8) Radiator
4) Circulating pump 9) Temperature sensor
5) Coolant temperature warning lamp 10) Heat exchanger (LDW 2004/T - 2204T).
Danger – Attention
- The uid coolant circuit is pressurized.
- Inspections must only be made when the engine has cooled and even in this case, the radiator or expansion
chamber plug must be unscrewed with the utmost caution.
- If an electric fan is installed, do not approach a hot engine since the fan itself could start up even when the engine is
at a standstill.
- Coolant uid is polluting, it must therefore be disposed of in the correct way. Do not litter.
COOLING SYSTEM