EasyManua.ls Logo

Lombardini CHD series - Cooling System Components; Expansion tank and cap; Checking for cooling system leaks; Coolant circulating pump

Lombardini CHD series
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 65 - Workshop Manual LDW CHD _ cod. 1.5302.345 - 6° ed_rev. 05
145
143
142
141
146
144
7
Expansion tank and cap
The expansion tank is separated from the radiator and is tted
withacoolantllcap.
The cap comes with vacuum valve 1 and pressure relief valve 2.
The pressure relief valve opens at a pressure of 0.7 bar.
Thermostat
1 - Air valve
Specications:
Opening temperature: 77°/81°C
Max. stroke at 94°C = 7.5 mm
Coolantowratewiththermostatandvalveinclosedposition=
15 Liters/h.
Coolant circulating pump
Impeller 3 and hub 5arettedtotheshaftbypresst.
To remove the impeller, screw the M 18x1.5 bolt into bore 2.
To remove that shaft take 4 which locks the bearing to the pump
body. A seal is located on the shaft between the bearing and the
impeller.
In case of worn-out seal, coolant leaks from hole 1.
LDW 1503 - 1603 - 2004 - 2204:
The ratio between the pump and engine rpm = 1:1.2
Pump delivery at 3000 rpm is 70 liters/min.
LDW 2004/T - 2204/T:
The ratio between the pump and engine rpm = 1:1.5
Pump delivery at 3000 rpm is 116 liters/min.
Checking for cooling system leaks
Remove the cap from the expansion tank and check coolant
level.
Replace the cap with one tted with portable hand air pump
couplingasshowninthegure142.
Compress air at a pressure of 1 bar for approximately 2 minutes.
Check that no leaks occur.
Caution – Warning
In very dusty working conditions verify and clean the
outside of the radiator frequently.
Replacecoolantasspeciedonpage22.