- 84 - Workshop Manual LDW CHD _ cod. 1.5302.345 - 6° ed_rev. 05
211
210
209
208
10
Fuel limiting device(g.208-209)
When starting up the engine the fuel limiting device has the aim
of preventing excessive smoke at the exhaust.
Use the delivery adjustment rod of the injection pumps 5 Fig.209
in a constant manner when ambient temperature is above 15°C.
As the temperature gradually falls, this device gradually lessens
its action to then exclude it at 0°C.
Application diagram for tampering system adjustment screw
and torque gearing device for EPA-approved engines
Components:
1 Breaking nut
2 STEI screw
3 Rivets (No.2)
4 TCEI screw
5Specialcoverxingscrew
6 Lower plate
7 Upper plate.
Stop setting
Unscrew the screw 2
Move rod 1 fully to the left.
Screw down screw 2 to touch rod 1.
Continue screwing screw 2 by 1/2 turn.
Lock nut 3.
Note: In these conditions the injection pump delivery control
limit stops cannot be damaged by violent impact caused
byoperationofanyelectro-stopsthatmaybetted.
Fuel limiting device adjustment(g208-209)
Take the engine to the setting speed and power
Loosen the lock nut 2.
Unscrew the screw 1 (to bring lever 4 close up to rod 5) until
the engine speed tends to decrease.
Screw the screw down by at most 1/2, 3/4 of a turn so as to
distance lever 4 from rod 5 by 1.2/1.8 mm.
Screw down the lock nut 2.
When the temperature falls under 0°C, lever A turns (pin 6 of
the thermostat 3 comes back in) to go into position B thereby
allowing rod 5 to go into the supplement position.
Settings