11
The cells Installed check them for serviceability,
for this aim, move curtains control key 14 so as is
shown in Fig. 6. Open the viewfinder. Looking
through the Inspection window 23 (Fig. 5), press
down the release knob 10 (Fig. 2) until It is
stopped slightly.
If the cells are serviceable and inserted in a
correct way, a red color indicator should shine at
the upper left corner of the viewfinder (Fig. 7). If
the Indicator does not shine, checkup whether
the cells are inserted in a correct way and contact
areas are clean. If the indicator does not yet
shine, replace all the cells.
Fig. 6.