Tensioni concatenate / Phase-Phase voltages / Tensions phase-phase / Tensione entre fases
NAVIGAZIONE FRA LE PAGINE DISPLAY DISPLAY PAGE NAVIGATION NAVIGATION SUR LES PAGES DE L’AFFICHEUR NAVEGACIÓN ENTRE LAS PÁGINAS VÍDEO
IN = Valore istantaneo
IN = Instantaneous value
IN = Valeur instantanée
IN = Valor instantáneo
HI = Valore massimo
HI = Highest value
HI = Valeur maxi
HI = Valor máximo
LO = Valore minimo
LO = Lowest value
LO = Valeur mini
LO = Valor mínimo
AV = Valore medio
AV = Average value
AV = Valeur moyenne
AV = Valor medio
GR = Barre grafiche
GR = Graphic bars
GR = Graphiques à barres
GR = Barras gráficas
Tensioni di fase / Phase voltages / Tensions de phase / Tensiones de fase
IN = Valore istantaneo
IN = Instantaneous value
IN = Valeur instantanée
IN = Valor instantáneo
HI = Valore massimo
HI = Highest value
HI = Valeur maxi
HI = Valor máximo
LO = Valore minimo
LO = Lowest value
LO = Valeur mini
LO = Valor mínimo
AV = Valore medio
AV = Average value
AV = Valeur moyenne
AV = Valor medio
GR = Barre grafiche
GR = Graphic bars
GR = Graphiques à barres
GR = Barras gráficas
Correnti di fase e neutro / Phase-Neutral currents / Courant de phase et neutre / Corriente de fase y neutro
IN = Valore istantaneo
IN = Instantaneous value
IN = Valeur instantanée
IN = Valor instantáneo
HI = Valore massimo
HI = Highest value
HI = Valeur maxi
HI = Valor máximo
LO = Valore minimo
LO = Lowest value
LO = Valeur mini
LO = Valor mínimo
AV = Valore medio
AV = Average value
AV = Valeur moyenne
AV = Valor medio
MD = Max demand
MD = Max demand
MD = Max demand
MD = Max demand
(continua) (continues) (continué) (sigue)
PAGINA ANALISI ARMONICA
Nel DMG800 è disponibile l’analisi armonica
fino al 31.mo ordine delle seguenti misure:
tensioni concatenate
tensioni di fase
correnti
Per ognuna di queste misure è disponibile una
pagina che rappresenta graficamente il
contenuto armonico (spettro) tramite un
istogramma a barre.
Ciascuna colonna rappresenta un ordine delle
armoniche, pari e dispari. La prima colonna
rappresenta il contenuto armonico totale (THD).
Ciascuna colonna dell’istogramma è poi divisa
in tre parti che rappresentano il contenuto
armonico delle tre fasi L1,L2,L3.
Il valore del contenuto armonico è espresso in
percentuale riferita alla ampiezza della
armonica fondamentale (frequenza di sistema).
E’ possibile visualizzare il valore del contenuto
armonico in forma numerica, premendo il
pulsante per attivare il cursore e poi
selezionando l’ordine desiderato tramite
s t
.
In basso vengono visualizzati una freccetta che
punta alla colonna e il contenuto armonico
percentuale delle tre fasi. Premere nuovamente
per uscire dal modo numerico.
La scala verticale del grafico viene selezionata
automaticamente fra quattro valori di
fondoscala, in base alla colonna con il valore
più alto.
HARMONIC ANALYSIS PAGE
The DMG800 provides the harmonic analysis
up to the 31st order of the following
measurements:
phase-to-phase voltages
phase-to-neutral voltages
currents
For each of these measurements, there is a
display page that graphically represents the
harmonic content (spectrum) through a bar
graph.
Every column is related to one harmonic
order, even and odd. The first column shows
the total harmonic distortion (THD).
Every histogram bar is then divided into three
parts, one each phase L1,L2, L3.
The value of the harmonic content is
expressed as a percentage with respect to the
fundamental (system frequency).
It is possible to show the harmonic content in
numeric format, pressing button to activate
the cursor and then selecting the required
order through
s t
. The lower part of the
screen will display a little arrow that points to
the selected column, and the relative
percentage value of the three phases. Press
once more to leave numeric mode.
The vertical scale of the graph is automatically
selected among four full-scale values,
depending on the column with the highest
value.
PAGE ANALYSE HARMONIQUE
L’analyse harmonique est disponible dans le
DMG800 jusqu’au 31ème rang des mesures
suivantes :
tensions entre phase
tensions phase-neutre
courants
Pour chaque mesure, vous disposez d’une
page représentant graphiquement le contenu
harmonique (spectre) à travers un
histogramme à barres.
Chaque colonne représente un rang des
harmoniques, pair et impair. La première
colonne représente le contenu harmonique
total (THD).
Chaque colonne de l’histogramme est partagée
en trois parties représentant le contenu
harmonique des trois phases L1,L2, L3.
La valeur du contenu harmonique est
exprimée en pourcentage se référant à
l’amplitude de l’harmonique fondamentale
(fréquence système).
Vous pouvez afficher la valeur du contenu
harmonique sous forme numérique, en
enfonçant la touche pour activer le
curseur puis en sélectionnant le rang voulu à
l’aide des touches
s
et
t
. Au bas de
l’afficheur, vous verrez une flèche pointant
vers la colonne et le contenu harmonique en
pourcentage des trois phases. Enfoncez de
nouveau pour quitter le mode numérique.
L’échelle verticale du graphique est
sélectionnée automatiquement parmi les
quatre valeurs de fond d’échelle, en fonction
de la colonne ayant la valeur la plus élevée.
PÁGINA ANÁLISIS ARMÓNICO
En DMG800 puede verse el análisis armónico
hasta el 31º orden de los siguientes parámetros:
tensiones entre fases
tensiones de fase
corrientes
Cada uno de estos parámetros tiene una
página específica que representa gráficamente
el contenido armónico (espectro) mediante un
histograma de barras.
Cada columna representa un orden de los
armónicos, pares e impares. La primera
columna representa el contenido armónico
total (THD).
A su vez, cada columna del histograma se
subdivide en tres partes que representan el
contenido armónico de las tres fases: L1, L2,
L3.
El valor del contenido armónico se expresa en
un valor porcentual que se refiere a la
amplitud del armónico fundamental
(frecuencia de sistema).
También es posible visualizar el valor
númerico del contenido armónico haciendo
clic sobre el pulsador para activar el
cursor y luego seleccionando el orden
deseado mediante los pulsadores
s t
.
Abajo se visualiza una flecha que apunta a la
columa y el contenido armónico porcentual de
las tres fases. Pulsar nuevamente para
salir del modo numérico.
La escala vertical del gráfico es seleccionada
automáticamente entre cuatro valores de
fondo de escala, en base a la columna con el
valor superior.
1 - Valori numerici dell’ordine selezionato
Numeric values of the selected order
Valeur numérique du rang sélectionné
Valores numéricos del orden seleccionado