(b) C
ount function of Revolution/Unit time is used to count the number of pulses for a
specified time while auxiliary mode enable signal is On.
(c) With the displayed number of pulses updated for a specified time and the number of
pulses per revolution input, Revolution/Unit time can be counted.
(d) Number of Revolution per 1 second is indicated after number of pulse per 1 revolution is
set and time is set to 1 second (1000ms). In order to indicate by Revolutions per minute
(RPM), the operation is executed in program.
(e) The example that number of pulse per 1 revolution set to ‘1’ and time is set to 1000 ms is
as shown below. (Ch0)
(f) In order to indicate revolution per minute (RPM), the program is as shown below. In case
of DMUL operation, RPM value is saved 64 bit in D100~D103. If operated RPM value is
used, it can use to Word or Dword type according to system (case of RPM value is small
number).
Command
Count value
1000
500
0
300
400
700
500
350
Revolution
per time
1000 1000 1000 1000
100 300 200 150