Chapter 2 System Configuration
2 -6
2.3 Basic System
2.3.1 Configuration method of Basic System
The features of Basic system consisted by connecting the main base and expanded base by a cable are
as follows. The number of steges of expanded base is limited according to the CPU type and the
allocation method of I/O No. is available to select the fixed type and variable type according to the
setting of basic parameter.
Classification XGK-CPUE XGK-CPUS XGK-CPUA XGK-CPUH XGK-CPUU
Max. expanded
stages
1 stage 3 stages 3 stages 7 stages 7 stages
Max. no. of I/O
Module install
24 Module 48 Module 48 Module 96 Module
Max. I/O point 1,536 points 3,072 points 3,072 points 6,144 points
Max. extended
distance
15m
Allocation of
I/O No.
(fixed type)
Each slot of base is allocated by 60 points regardless module installation and type.
For one base, I/O no. of 16 slots is allocated. That is, the start no. of No.1 base becomes
P00640. (Refer to 2.3.2)
The example of I/O no. of 12 Slot base is as below :
0 12345678910 11
P0
~
P3F
P40
~
P7F
P80
~
P11F
P120
~
P15F
P160
~
P19F
P200
~
P23F
P240
~
P27F
P280
~
P31F
P320
~
P35F
P360
~
P39F
P400
~
P43F
P440
~
P47F
I : input, O : output
Allocation of
I/O no.
(variable type)
The point is allocated according to the assignment of installation module per slot.
- If assigned installation module by I/O parameter, the assigned point is allocated.
- The slot not assigned by I/O parameter shall be allocated automatically according to actual
installation slot
(Note: 8 point module shall be allocated by 16 point.)
- The empty slot not assigned by I/O parameter shall be processed by 16 point.
Available to assign the point only by I/O parameter without module assignment.
The slot installed by special module or communication module is allocated by 16 point.
The example of I/O no. of 12 Slot base is as below :
0 12345678910 11
P00
~
P0F
P10
~
P1F
P20
~
P3F
P40
~
P7F
P80
~
P8F
P90
~
P10F
P110
~
P12F
P130
~
P16F
P170
~
P18F
P190
~
P19F
P200
~
P21F
P220
~
P23F
I : input, O : output
Notes
1) The allocation method of I/O no. shall be set in basic parameter.
2) For Main base, the base no. is fixed as “0” and the expanded base has a switch to set the base no.
3) In case of setting module type by I/O parameter, it starts the operation when the type of actually installed
module is matched.
P
W
R
I
1
6
I
1
6
I
3
2
I
6
4
O
1
6
O
3
2
O
3
2
O
6
4
I
3
2
O
3
2
O
1
6
O
3
2
C
P
U
Slot No.
P
W
R
I
1
6
I
1
6
I
3
2
I
6
4
O
1
6
O
3
2
O
3
2
O
6
4
I
3
2
O
3
2
O
1
6
O
3
2
C
P
U
Slot No.

Table of Contents