Chapter 3. Standard Specification
3-6
Item
XP50-TTE/DC
XP50-TTA/DC
XP70-TTA/DC
XP80-TTA/DC
RS-422/485 Terminal Block 1 Channel, RS-422/485 mode
CF Card - 1 Slot (Compact Flash)
Expansion module - Option module is available
Multi-language
Up to 8 language simultaneously
Animation
GIF format is available
Recipe
available
Data logging
available
Script executor
available
Certifications
CE, UL, KC
Protection standard IP65F
Dimension (mm)
240 x 174 x 63 240 x 174 x 73 317 x 243 x 73
Panel cut (mm)
228.0 x 158.0 294.5 x 227.5
Rated voltage
DC24V (Actual Range: 19.2 ~ 28.8V)
Power
consumption(W)
13 20 27 30
Weight(Kg)
1.2 1.4 2.2 2.4
Remark
(1) Notice in connecting with power
: Connecting AC power to the device using DC power may cause product break or fire. Be careful when connecting
(2) FG connection
: Use
⑤
FG terminal (Chapter 2.1) for FG of the device.
⑮
FG (Chapter 2.1) is for FG terminal of extension card.
(Except XP30-BTE, XP30-TTE and XP50-TTE)
(3) Prevention tape of Battery discharge
: There is prevention tape is to prevent the battery discharge. In order to use backup, remove the prevention tape.
(4) Battery operation and duration
: Battery is used to reserve backup data and RTC (data/time) when power is off.
Because battery is used when power is off, battery is not consumed when power is on.
(5) LCD Backlight replacement
: XP40-TTA(TTE)/DC, XP50-TTA(TTE)/DC, XP70-TTA/DC, XP80-TTA/DC, LCD backlight is replaceable.
However in XP30-BTE/DC, XP30-TTE/DC, XP30-BTA/DC and XP30-TTA/DC, LCD backlight is not
replaceable because LCD and backlight is all-in-one type.