Chapter 12. EMC Standard Certification
Chapter 12 EMC Standard Certification
12.1 Requirement for EMC Standard Certification
EMC command is regulated on “It doesn’t produce the Strong electromagnetic waves: Emission” and “It is not affected by
electromagnetic wave from external: Immunity”. The following is describing the contents to meet the EMC command when configuring
the system by using the XGT Panel. This is a summary document for the request and standard which our company has obtained
from EMC but we don't assure that all devices manufactured according to these contents are not suitable for the below standards. The
final manufacturer needs to finally judge about the fitness method or fitness judgment of EMC command.
12.1.1 CE standard certification
Applied Standards Results
1. Emission
Conducted Disturbance EN61000-6-4:2007 C
Radiated Disturbance EN61000-6-4:2007 C
Harmonic Current Emission EN61000-3-2:2006 / A2 : 2009
NA
NT
주
3)
Voltage Change, Fluctuations and Flicker EN61000-3-3:2008
NA
NT
주
3)
2. Immunity
Electrostatic Discharge
EN61000-6-2:2005
C
EN61000-4-2:2009
Radio-Frequency Electromagnetic Field
EN61000-6-2:2005
C
EN61000-4-3:2006 / A1 : 2008
Fast Transient
EN61000-6-2:2005
C
EN61000-4-4:2004
Radio-Frequency Continuous Conducted
EN61000-6-2:2005
C
EN61000-4-6:2009
Power-Frequency Magnetic Fields
EN61000-6-2:2005
C
EN61000-4-8:1993 / A1 : 2001
Surges
EN61000-6-2:2005
C
EN61000-4-5:2006
Voltage Dips and Interruptions
EN61000-6-2:2005
NA
주
2)
C
주
3)
EN61000-4-11:2004
RE1) C=Conform NC=Not Conform NT=Not Tested NA=Not Applicable
RE2) Applicable to the only XP30-BTA(BTE)/DC, XP30-TTA(TTE)/DC, XP50-TTA(TTE)/DC, XP70-TTA/DC, XP80-TTA/DC
XP40-TTA(TTE)
RE3) Applicable to the only XP70-TTA/AC, XP80-TTA/AC, XP90-TTA/AC