4)BATTERY+VE:Connect+VEterminalofbatterybank.
5)BATTERY-VE:Connect-VEterminalofbatterybank.
6)BATTERYMCB:Usedtoconnect/disconnectbatterybank.
7)EARTH:UsedtoconnectEarthwire.
8)GRIDINPUTMCB:Usedtoconnect/disconnectGridSupplySource.
9)GRIDINPUTL:ConnectlineofGridSupplySourcetothisterminal.
10)GRIDINPUTN:ConnectNeutralofGridSupplySourcetothisterminal.
11)GRIDINPUTFORINVERTERN:ConnectneutralofconnectedUPS/Invertertothisterminal.
12)GRIDINPUTFORINVERTERL:ConnectlineofconnectedUPS/Invertertothisterminal.
13)BATTERYTYPESWITCH:UsedtoselectbatterytypeasperbatteryinstalledwithUPS/Inverter.
14)CHG.MODESELECTIONSWITCH:SelectmodeasperavailabilityofSolar&GridSupplySource.
UserSelectableSwitches:
AUTOMODE-SystemwillworkoninternalalgorithmasperavailabilityofSolarandGridpowersourcewithoptimumbalanceinbackup&
savings.
PVCHG.-UnitwillworkonmaximumsolarutilizationmodeirrespectiveofGridpowerbeingavailable.Recommendedforareaswherepower
cutsareverylessorlimited.
PV+GRIDCHG.-WillactasanadditionalsolarchargerwithUPS/Inv.chargeruptocertainbatteryvoltage.Recommendedforareaswhere
powercutsareveryhigh.
SMF/FLATPLATE/TUBULAR-AsperbatterytypeinstalledwithUPS/Inv.