Page 35
Section 11 – Summary Tables
GENERAL USER-PINCODE FUNCTIONS SUMMARY
Function Press Procedure
Full Set User or Secondary Pincode
Press Full
X-X-X-X
Full
Part Set User or Secondary Pincode
Press P1, P2 or P3
X-X-X-X
P1, P2 or P3
Unset User or Secondary Pincode X-X-X-X
Omit zones User Pincode
Press Program
Press P1, P2 or P3
Choose zones
Press Omit to confirm zone
Press Store
X-X-X-X
PG
P1, P2 or P3
Display
Omit
Store
Walk Test User Pincode X-X-X-X
IN ORDER to activate the user pincode functions, the system must be unset and user pincode must
be entered.
USER-PINCODE PROGRAM FUNCTIONS SUMMARY
Function Press Procedure
Program a cordless detector PG-1 Press “Display” to select a zone to learn and press “Store”
Delete a cordless detector PG-2 Press “Display” to select a zone to delete and press “Store”
Program siren duration PG-3 Enter desired time (01-20) and press “Store”
Siren test PG-4 Wait for 30 seconds for the siren to stop or press “Reset”
Strobe test PG-5 Wait for 30 seconds for the strobe to stop or press “Reset”
Program “Chime Zone” PG-6 Press “Display to select a zone to chime and press “1” to
activate or “0” to deactivate. Press “Store” to confirm or
“Reset” to deny.
Program Entry/Exit time PG-7 Enter desired time (10-60) and press “Store”
Program new user pincode PG-8 Enter desired user pincode and press “Store”
Program new secondary
pincode
PG-9 Enter desired secondary pincode and press “Store”
Recall alarm events PG-0 Page through events by pressing “Display”
IN ORDER to activate the engineer pincode functions, the system must be unset and engineer
pincode must be entered.
ENGINEER-PINCODE PROGRAM FUNCTIONS SUMMARY
Function Press Procedure
Select walk-through zones PG-91 Press “Display to select a zone and press “1” to
activate or “0” to deactivate. Press “Store” to
confirm or “Reset” to deny.
Select Entry/Exit zones PG-92 Press “Display to select a zone and press “1” to
activate or “0” to deactivate. Press “Store” to
confirm or “Reset” to deny.
Full alarm for tamper in standby
mode
PG-93
Remote disarm requires entry timer PG-94
Silent personal attack PG-95
Enable/disable secondary pincode PG-96
Engineer-only reset PG-97
On/Off supervisory PG-98
To set those function on – press 1
To set them off – press 0
Press “Store” to confirm or “Reset” to deny.
Setting new engineer code PG-99 Enter desired engineer pincode and press “Store”
Reset all functions PG-90 Press three times on the “Store” button to erase
system memory.