APx500 Flex Setup Guide
Lynx Aurora
(n)
Overview
The Lynx Aurora
(n)
is a modular device which can come in a variety of configurations. The following
setup guide is intended for use with the variant which has 16 channels of line I/O and a USB interface.
Follow the steps below to set up your device for use with APx500 Flex.
Driver installation
1. Connect a powered Lynx Aurora
(n)
to your computer.
2. Download the latest device driver for your operating system from the Lynx website.
3. Install the driver.
Device configuration
1. Ensure the Meters page is visible on the Main Display of the Aurora. If it isn’t, press the
Meters/Exit button.
2. Press the Function button.
3. Highlight “Line Trim” using the Function button.
4. Press Select.
5. Ensure all line inputs are set to +4 dBu.
6. Ensure all line outputs are set to +4 dBu.
7. Press Meters/Exit.
8. Use the Function button to highlight “Routing” and press the Select button.
9. Ensure that “USB Play” is the only item enabled under “To Line Out”.
10. Ensure that “Inputs” is the only item enabled under “To USB”.
11. Press Meters/Exit twice to return to the Meters page.
Calibration
Once the ASIO interface has been configured, the input and output sensitivities of the device should
be entered into the APx500 software so that signals can be generated and acquired accurately in analog
units. A project file template, pre-configured for this device, has been included with APx500 Flex. It can
be accessed from the FileNew Projectmenu item.
Alternatively, to manually calibrate the output and input,
1. Run APx500 Flex.
2. Set “Device” to “ASIO Lynx Aurora USB”.
3. Set the output “Scaling Mode” to “Analog”.
4. Set the single output scaling factor to the appropriate value from the “Output Sensitivities”
table below, depending on which output is to be used.
5. Set the input “Scaling Mode” to “Analog”.
Set the input scaling factor of each channel to the value in the “Input Sensitivities” table below.
(ES) Equipements Scientifiques SA - Département Tests & Mesures - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 45 - Fax. 01 47 01 16 22 - e-mail: tem@es-france.com - Site Web: www.es-france.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx Aurora (n) and is the answer not in the manual?

Lynx Aurora (n) Specifications

General IconGeneral
Channels8
Sample Rate192 kHz
Bit Depth24-bit
ConnectivityUSB, Thunderbolt
Outputs8 analog, 8 digital
Dynamic Range120 dB
THD+N-110 dB
ClockInternal