Dupa ce initierea primei porniri este realizata,
dispozitivul este pregatit sa functioneze in Modul
Automat (modul de operare F0 -vezi sectiunea 5)
PresSystem porneste pompa cand presiunea
masurata (LED Pressure) scade sub nivelul
presiunii minime (LED PR.RESTART) cand
exista cerere de apa.
PresSystem opreste pompa cand presiunea
masurata atinge presiunea maxima setata, cand
nu mai exista cerere de apa. Ledul Pump ON
lumineaza intermitent. In aceste conditii,
PresSystem nu opreste pompa imediat, ci dupa
aproximativ 20 secunde
After the phase of the first startup the device is
ready for automatic operation (operation mode
F0 see paragraph 5).
PresSystem starts the pump when the measured
pressure (LED PRESSURE) falls below the
restart pressure (LED PR.RESTART) at the
request of water.
The PresSystem turns off the pump when the
measured pressure reaches the maximum
pressure stored at the end of request water. The
led PUMP ON starts flashing. In these
conditions, the PresSystem turns off the pump
not immediately but after about 20 seconds.