What to do if the Magen eco-Energy resilience D chlorine level is low?
- CChristopher RichardsAug 18, 2025
If the chlorine level is low, here are some possible causes and solutions: * The system might be turned off. Turn the system on to the desired setting. * The output level may be set too low. Set the output bar to a higher setting and/or increase pump operation time. * The salinity might be low. Check the salinity level. * The pump operation time may be too short. Run the pump at least eight hours per day or more if necessary. * The stabilizer (cyanuric acid) could be low. Check water chemistry; stabilizer should be 60-80 ppm. If low, add stabilizer. * Phosphate levels might be high. Check phosphate levels at your local professional and reduce to below 100 ppb. * There may be a chemical imbalance. Check other chemistry and balance chemicals.