-Temperature: Choose Celsius or Fahrenheit
7. Other functions:
Adjustments and corrections can be done from this menu. Attention: Adjustments can have a big
influence on the working of the thermostat! Please consult your supplier.
The following options are:
Heating system:
- Type of heating system
- Installation depth of the system (floor heating)
- Floor covering: wood or other
- Temperature
These settings can be changed using the start up wizard.
- Calibration; a correction can be made here on the sensor temperature in the display and the
measured floor or room temperature. Consult your supplier before changing calibration setting.
- Intelligence; Switch the intelligent function on or off.(Default is ON)
See Ref 2.3
- Differential: the difference between switch on and off period during heating time.
Consult your supplier before changing differential settings.
- Pilot function: Can be used to operate the thermostat through an external source. This can be a
central source or a smart home system. This function can be turned on or off.
- Sensor type; gives the possibility to adjust the sensor value. This is not required in a standard
situation. Consult your supplier before changing sensor type.
- Start up wizard; starts the configuration wizard.
- Reset; all settings are restored to the factory default settings. To confirm hold the right button for 5
seconds to activate the reset. The thermostat reverts back to the start up wizard.
2. General information:
Explanation of LED colours / signals:
Red: power consumption
Green: system operational
Red light flashing on and off: Sensor fault. (Ref 2.2)
Explanation of text / Symbols in the main screen:
- Comfort period
- Limited floor temperature achieved (28 ºC)
- Child lock activated
- Electrical use for heating
- Following symbols only in combination with an active Pilot function:
- Set back: standard set back temperature (pilot wire)
- Set back: anti frost + 7 degree Celsius( pilot wire)
- Set back: thermostat off (pilot wire)
- Set back: effective temperature -1 degree Celsius (pilot wire)
- Set back: effective temperature -2 degree Celsius(pilot wire)
Sensor error / fault: