C-92
35 Series 4WD, Model - 3535, 4035, 4535 and 5035 SM June’08
G. AIR CLEANER SERVICE INDICATOR
It is fitted on air cleaner outlet connecting to air intake
manifold. This is a mechanical type indicator set to
80 milli-bar vacuum in intake system. The red band will
be visible in the transparent cover, when the 80 milli-
bar vacuum is reached. At this stage air cleaner has to
be cleaned / Serviced.
After servicing, reset the clog indicator by pressing
rubber cap. (As marked in the figure).
Ensure red band will move to the
original position after resetting.
Air Cleaner
Red Flap