P2147: Injector bank short circuit to groung
Either of these pins if they are short to ground will cause the error :
7 or 6 or 44 or 25 or pin 63.
Effect: Lamp will be continuously ON.
Engine will switch OFF.
Possible causes:
1. Wire short to earth
2. Defective injector or defective EMS ECU
Corrective action: Check for the pin bent/ wire cut and shorted.
Defective injector
EMS ECU
P2147
P2148