EasyManua.ls Logo

Mahindra GIPPSAERO GA8-TC 320 - Fires

Mahindra GIPPSAERO GA8-TC 320
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 3
Model GA8-TC 320 Emergency Procedures
CASA Approved
Page 3-6 5 Feb 2009 C01-01-08
3.3.3. Fires
During Start On Ground
1. Cranking ...............................................CONTINUE, to get a start which would suck the
ames and accumulated fuel through the fuel injector
and into the engine.
If engine starts:
2. Power ................................................... 1700 RPM for a few minutes
3. Engine .................................................. SHUTDOWN and inspect for damage
If engine fails to start:
2. Cranking .............................................. CONTINUE
3. Throttle ................................................. FULL OPEN
4. Mixture ................................................. IDLE CUT OFF
5. Fuel Shutoff Valve ................................ OFF
6. Ignition ................................................. OFF
7. Master Switches Bus 1 & Bus 2 ........... OFF
8. Aircraft .................................................. EVACUATE
and extinguish re using best available means.
Engine Fire In Flight
1. Fuel Shutoff Valve ................................ OFF
2. Fuel Pump ........................................... OFF
3. Throttle ................................................. CLOSED
4. Propeller .............................................. COARSE
5. Mixture ................................................. IDLE CUT OFF
6. Cowl Flap ............................................. CLOSED
7. Master Switches Bus 1 and Bus 2 ....... OFF
8. Vents .................................................... CLOSE HEATER AND AIR VENTS
9. Airspeed ............................................... 140 KIAS to try to blow re out.
INCREASE UP TO V
NE
if required.
10. Forced Landing .................................. EXECUTE. Refer paragraph 3.3.2
Electrical System Overheating In Flight
1. Master Bus 2 ........................................OFF
2. Flight ....................................................CONTINUE cautiously
3. Land .....................................................AS SOON AS PRACTICAL
Electrical Fire In Flight
1. Master Switches Bus 1 and Bus 2 ....... OFF
2. Electrical Switches ............................... OFF
3. Extinguisher ......................................... ACTIVATE
If re goes out:
4. Smoke .................................................. USE OXYGEN IF AVAILABLE.
VENTILATE CABIN
5. Precautionary Landing ......................... AS SOON AS PRACTICAL
01 Aug 2011

Table of Contents