CONTINIOUS TORQUE MONITORING
DTC Description
P1633 ECU Monitoring: PoI2 qty error
P1634 ECU Monitoring:PoI2 shut off error
P1635 ECU Monitoring:PoI3 efficiency factor error
P1637 ECU Monitoring: Injection quantity correction error
P061B ECU Monitoring: Torque comparison error
P163E ECU Monitoring: Torque monitoring level2 error
P1639 ECU Monitoring: Lead torque monitoring level2 error
P163D ECU Monitoring: Set torque monitoring level2 error
DTC INFORMATION
PROBABLE CAUSES OF
FAILURE
NORMAL OPERATION
Ignition ON
The voltage monitoring of the injector energizing time is
found normal
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
The difference between the programmed energizing time
and the measured energizing time exceeds the limit
DTC REACTIONS
Engine Check lamp continuosly ON
HEALING CONDITION
Ignition Off/On
Faulty EMS ECU