MAN B&W 16.02
Page 6 of 6
MAN Diesel
MAN B&W ME-GI engines 198 86 58-1.2
Gas Injection (GI) Extension
GPCU
GPSU
GPSU – Gas Plant Safety Unit
GPCU – Gas Plant Control Unit
GACU – Gas Auxillary Control Unit
GCSU – Gas Cylinder Safety Unit
ME-ECS
Network
ECR – Engine Control Room
HC Sensor – Hydro Carbon Sensor
ME-ECS – Electronically Controlled Engine Control System
# ~ Cylinder number
Network
Safety
System
Engine Shut Down
XC2001
ELWI Enable
XC6360
Bridge
GCSU1
Double Wall
Pipe
Ventilation
Running
Plant: Flow Switch
Run/Stop
Safety: Flow Switch
XC6312
XC6301
FS6302
FS6303
Double Pipe HC Sensor B
XT6332-B
Double Pipe HC Sensor A
XT6332-A
Dry Air Flow Switch
Dry Air Valve Control
ZV6307
FS6305
ECR
Panel
Emg. Gas Shutdown ECRXC6365
Gas
Return
System
(Optional)
Gas Return System Ready
XC6053
Plant: Gas Return Valve Opened
XC6050
Plant: Gas Return Valve Closed
ZS6051
P: Gas Return Tank Valve Ctrl
ZS6052
XC6060
XC6061
XC6062
P: Gas Return Bleed Valv Opened
ZS6065
ZS6066
P: Gas Return Bleed Valv Closed
S: Gas Return & Bleed Valve Ctrl
S: Gas Return Bleed Valv Opened
S: Gas Return Bleed Valv Closed
Gas
Bleed
Valve
Gas Bleed Valve Opened
Gas Bleed Valve Closed
Gas Bleed Valve Close
Plant:
Main
Gas
Vavle
Plant: Main Gas Valve Opened
Plant: Main Gas Valve Closed
Plant: Main Gas Valve Open
Safety:
Main
Gas
Valve
Safety: Main Gas Valve Opend
Safety: Main Gas Valve Closed
Safety: Main Gas Valve Open
XC6014
ZS6010
ZS6011
ZS6015
ZS6016
ZS6012
ZS6013
XC6018
XC6019
Gas Train
Gas Supply Pressure
Gas to Engine Pressure
Gas Train Pressure
PT6017
PT6024
PT6006
Gas Pressure
Measurements
Return
Pipe
Test
Valve
Return Pipe Test Valve Opend
Return Pipe Test Valve Closed
Return Pipe Test Valve Close
ZS6377
ZS6376
XC6375A
Valve Control Air Pressure
PT6025
Gas Valve Train Power Failure
XC6306
GACU
Gas
Monitoring
Control
Gas calorific value
Gas Supply Pressure Set Point
Gas flow
Actual Gas Load
XC6005
XC6028
XC6008
XC6009
Gas Standby Request
XC6030
Fuel Gas
Supply System
Gas Supply Running
Gas Supply Ready / Local-Fail
Gas Supply Run / Stop
XC6003
XC6001
XC6002
Gas Mass Flow Rate Limit
XC6070
Gas Temperature
XT6070
Inert Gas
System
Inert
Gas
Valves
Inert Gas Supply Valve Opened
Inert Gas Supply Valve Closed
Inert Gas Supply & Block Valve Open
Inert Gas Pressure
Inert Gas Block Valve Opened
Inert Gas Block Valve Closed
XC6320
ZS6020
ZS6021
ZS6022
ZS6023
PT6321
Inert Gas Bleed Valve Opened
Inert Gas Bleed Valve Closed
ZS6316
ZS6317
Plant: Return Pipe HC Sensor
Safety: Return Pipe HC Sensor
XT6331-A
XT6331-B
Alarm System
External Gas Shut Down Req.
Power Failure
System Failure
XC2211
XC2222
XC2212
Double Pipe HC Alarm
XC2213
Gas Mode for LOP indication
Local
Operating
Panel
XC6362
Gas Mode for Bridge indication
Emg. Gas Shutdown Bridge
XC6370
External To
Machinery
Space
Emg.Gas SD Ext. Machinery Space XC6371
XC6361C
GI Extension Interface to External Systems
Fig. 16.02.03: Interface to external systems with basic information of flow in and between external systems
Further to the alarm sensors, local instruments
and control devices listed in Section 18.04-06,
the GI extension interface to external systems is
shown in Fig. 16.02.03.
309 23 84-2.0.1