1-15
I
NSTRUCTIONS
FOR
WELDING
AND
BLOW
TORCH
WORK
ON
THE
EXTERNAL
STRUCTURE
Ensure that there are no hydraulic or electrolyte leaks on the platform.
When welding, work in the opposite direction from the control console to avoid sparks damaging it .
- Any welding and cutting (blow torch) work from the basket on a building’s metallic structures requires the following precautions
to be taken:
A - WITH ELECTRIC WELDING EQUIPMENT
- It is essential that the machine has a discharge braid connecting the platform’s chassis to the ground.
- It is also essential that the external structure to be welded is connected to the earth. If the above conditions are observed,
the platform can, in this case, be in contact with the structure or the elements to be welded without damaging the electronic
components.
- The power supply to the welding equipment must be via an earthed socked and any extension required just also be earthed.
- In all cases, ensure that there are no electrical arcs in the basket or on the platform (contact between the brazing rod or the torch
and the welding equipment’s earth). To ensure this, at any time the welding equipment’s earth must not be positioned on the
platform’s basket but instead only as close as possible to the element to be welded.
- Switch off the welding equipment before disconnecting the earth clamp from the element or elements to be welded.
B - WITH A BLOW TORCH
- Attach the blow torch’s bottles to the basket’s handrails.
- Instructions for welding and blow torch work on the external structure
- Do not set the blow torch down on the lip of the basket while it is still operating or point it towards the control console or its power
cables.
1-151-15
547408 EN (15/05/2012)