ELECTRICITY
116
547379EN
80 (08/03/2017)
VARIABLE SPEED CONTROLLERS WIRING
Control circuit - Electronic module
Base module control unit Measure using the calibrator Multimeter
Connector PIN Wire N° Signal Type of signal Menu Description Not activated Activated Not activated Activated
A
1 128 +10.5V Not used NOT MEASURABLE
2 128 0V NOT MEASURABLE
4 +10.5V Not used NOT MEASURABLE
5 113 CAN-L NOT MEASURABLE
6 112 CAN-H NOT MEASURABLE
B
1 106 Power supply Incoming
2 119 Pressure switch Incoming 1.3.13 Brake release Open Closed +48V
3 117 Arm down SQ1a Incoming 1.3.11 Boom rest Open Closed _ (1)
5 108 Base selector Incoming 2.6.11 Lower box select Open Closed 0V (5)
6 118 Telescope retracted SQ4a Incoming 1.3.12 Tele sw Open Closed 0V (2)
8 102 Line switch Outgoing 0V
9 130 Pump/traction switch Outgoing 0V (4)
10 Free
11 121 Switch KM2 Outgoing
1 - See operation of brake release electrical circuit.
2 - 0 V when the base/basket selector is set to base.
3 - 0 V in transport position only.
4 - 0 V only during hydraulic movements (except for travel, left/right steering, and supplying brakes).
5 - See tilt sensor settings for operating conditions (6TILT SENSOR SETTINGS, 5 126)
80 - 98
80 - 99
BA