G3 – OVERHEAD GUARD OR CAB IN THE EVENT OF A FAILURE
LIFTING
IMPORTANT
The lifting procedure is a delicate and dangerous operation that must be carried out with care.
Check that there is nothing laying on the driver’s seat, which could disrupt the operation.
Tilt the mast as far forward as possible in order to avoid colliding with the lifted cab.
PROCEDURE IN THE EVENT OF HYDRAULIC FAILURE ON THE LIFTING SYSTEM
UNLOCKING THE OVERHEAD GUARD OR THE CAB:
- Unlock the overhead guard by means of the lever 1 in position A.
- With the cab model, close the doors.
UNLOCKING THE LIFTING CYLINDER
- Unscrew lifting cylinder feed screw via the access panel situated beneath the lift truck.
IMPORTANT
Dispose of the drain oil in an ecological manner.
RAISING THE OVERHEAD GUARD OR THE CAB:
- Unscrew the two screws 2 on the roof and replace them with two MANITOU eyes
3 Reference 72422.
- Use a pulley or winch (minimum load capacity 2000kg) as well as a sling (CMU
2000kg).
- Pass sling through pulley block and attach the ends of the sling to rings 3.
- Slowly lift the cab using the hoist until you are able to place the safety prop 4 in
its holder 5.
3 - 30
2
2
1
BA
4
5
3
3
647468 (26/11/2018)
SI 25/30/35 ... 4ST3A ; MH 25-4 ... 4ST3A