OCCASIONAL MAINTENANCE
CLEAN "Stationary lift truck" exhaust purification
t
IMPORTANT
t
Exhaust purification is an automated procedure activated by the operator when the following indicator lamps are
displayed:
or +
- Park the lift truck in a safe and adequately ventilated place.
- Check the following points:
• forward/reverse selector in neutral,
• parking brake applied,
• boom angle less than5°,
• accelerator pedal released,
• hand throttle not used (option),
- Check that the fuel level is sufficient.
- Start the lift truck and run the engine for a few minutes to bring it up to its operating temperature.
- Press the top of switch1 for more than two seconds to begin the regeneration procedure.
- Lighting of the indicator lamp
plus a beep conforms the start of the “stationary lift truck” exhaust purification
procedure.
- The "wait" display will flash throughout the ‘stationary lift truck’ exhaust purification.
- Otherwise, "notice" will be displayed for3 seconds indicating a fault in the procedure. In this event check the positioning
of the lift truck and contact your dealer if necessary.
- At the end of the procedure, indicator lamps
+ go out.
- During the procedure the engine speed increases to approx.1800 rpm, and the indicator lamp
comes on when
the exhaust particle filter gases reach a high temperature.
t
IMPORTANT
t
The exhaust sublimation procedure must only be stopped if absolutely necessary.
The procedure stops automatically if the operator:
- activates the hydraulic control joystick,
- engages forward or reverse gear,
- switches off the engine,
- or pressing on the top of the switch1.
- The time taken for exhaust purification varies (between15 and30 minutes) according to several criteria, such as:
• the level of clogging of the filter,
• the ambient temperature,
• the fuel quality and type of engine oil,
• the number of exhaust particle filter automatic regeneration requests previously cancelled.
- The engine will return to its initial idling speed to indicate that the procedure has finished.
t
IMPORTANT
t
Once the exhaust sublimation procedure is completed, leave the engine idling for a few minutes to lower the temperature before switching off the ignition.